Designation Description Standards Observations
Power supply and consumption
Primary voltage range 36 V to 60 V
none–referenced
48 V rated voltage
Maximum consumption < 1kW
ETSI ETS 300 132
including 8 RBS
Protection
overvoltage, short–circuit (40
A fuse), polarity inversion,
thermal protection (ventilation
failure)
ETSI ETS 300–132
Physical interfaces: ATM network interface (UNI)
Connector type SC/PC ITU–T.432.2/§3.1
1300 nm
1 for each direction
Medium
single mode fiber
(SMF; 9/125 µm)
ITU–T G.652
1300 nm
1 for each direction
Environment class 1 LASER product IEC 825
Bitrate
nominal
tolerance
155.520 Mbps
+/– 20 ppm
ITU–T.432.2/§3.1
Line coding NRZ
Instability cf. standard masks ITU–T G.958
Physical interfaces: E1, TDM circuit interface (75/120 )
standard DBS female sub–D pins
8 connectors, 8 TDM
interfaces per connector
75 interface BNC or 1.6/5.6 connector 1 per direction
120 interface STP specific connector 1 per direction
Nominal bitrate 2.048 Mbps (+/– 50 ppm) ITU–T G.703/§6.1
Line coding HDB3
tolerated input jitter
residual output jitter
cf. standard template
ITU–T G.823/§3
ITU–T G.823/§2
Environmental specifications
DBS Classification
ETS 300 019–2–3
IEC 721 3–3/
classes 3K5–3Z2–
3Z4–3B1–3C2–3S2
–3M1
Operating temperature –5°C to + 55°C
Relative humidity
at 30°C
93%