To reboot the switch from the working directory, enter the following command at the prompt, along with a
time out period (in minutes), as shown:
-> reload working rollback-timeout 5
At the end of the timeout period, the switch will reboot again normally, as if a reload command had been
issued.
Rebooting the Switch from the Working Directory with No Rollback Timeout
It is possible to reboot from the working directory without setting a rollback timeout, in the following
manner:
-> reload working no rollback-timeout
Scheduling a Working Directory Reboot
It is possible to cause a working directory reboot of the CMM at a future time by setting time parameters
in conjuction with the reload working command, using the in or at keywords. You will still need to spec-
ify a rollback timeout time, or that there is no rollback.
To schedule a working directory reboot of the CMM in 3 hours and 3 minutes with no rollback timeout,
you would enter:
-> reload working no rollback-timeout in 3:03
To schedule a working directory reboot of the CMM at 8:00pm with a rollback timeout of 10 minutes, you
would enter:
-> reload working rollback-timeout 10 at 20:00
Note. Scheduled reboot times should be entered in military format (i.e., a twenty-four hour clock).
Cancelling a Rollback Timeout
To cancel a rollback timeout, enter the reload cancel command as shown:
-> reload primary cancel
or
-> reload cancel
The reload working command is described in detail in the OmniSwitch CLI Reference Guide.