User guide
Managing CMM Directory Content Managing the Directory Structure (Non-Redundant)
OmniSwitch 6250/6450 Switch Management Guide May 2012 page 5-23
Show Currently Used Configuration
When a switch is booted, the certified and working directories are compared. If they are the same, the
switch runs from the working directory. If they are different, the switch runs from the certified directory.
A switch running from the certified directory cannot modify directory contents. (This topic is covered in
“Where is the Switch Running From?” on page 5-4.)
To check the directory from where the switch is currently running, enter the following command:
->show running-directory
CONFIGURATION STATUS
Running CMM : PRIMARY,
CMM Mode : DUAL CMMs,
Current CMM Slot : 1,
Running configuration : WORKING,
Certify/Restore Status : CERTIFY NEEDED
SYNCHRONIZATION STATUS
Flash Between CMMs : SYNCHRONIZED,
Running Configuration : NOT AVAILABLE,
Stacks Reload on Takeover: ALL STACKs (SW Activation)
The command returns the directory the switch is currently running from (working or certified) and which
CMM is currently controlling the switch (primary or secondary). It also displays whether the working and
certified directories are the same, and if a synchronization is needed between the primary and secondary
CMM.
The show running-directory command is described in detail in the OmniSwitch 6250/6450 CLI Refer-
ence Guide.