User guide

Connecting Chassis to Power Source Mounting OS6400 Switches
page 3-22 OmniSwitch 6400 Series Hardware Users Guide July 2010
4 Tighten the clamp by tightening the screw above the slot into which you inserted the wire lead. The
wire lead should be securely attached inside the connector. You should be able to pull on the wire and not
dislodge it.
Warning. The positive (+) wire of the sourcing equipment, such as a battery or rectifier, must be
connected to the positive (+) terminal of the OmniSwitch DC power supply and the negative (-) wire of the
sourcing equipment must be connected to the negative (-) terminal of the OmniSwitch DC power supply.
5 Repeat Steps 2 through 4 for the remaining positive and negative wire leads.
Correct Polarity Connections
DC Power Source
OS6400 Power Supply