Specifications

Alcatel-Lucent Page 13
OmniSwitch 6850 Series
The 10G-XFP-LR is a long-reach 10-Gigabit optical transceiver that supports single mode fiber over 1310 nm wavelengths.
The 10G-XFP-LR supports 10-micron fiber up to a maximum distance of 10 kilometers.
The 10G-XFP-SR is a short-reach 10-Gigabit optical transceiver that supports multimode fiber over 850 nm wavelengths. The
10G-XFP-SR supports 50/62.5 micron fiber up to a maximum distance of 300 meters (depending on the grade of fiber used).
Hardware Architecture
MAC Address Table (L2 Unicast MAC addresses) Up to 16 K (16,384) MAC Addresses is supported per system. 4.1.10
IP Address Table Routes (RIB) 48K routing table
L3 IPv4 Host Entries (FIB) 8K
L3 IPv4 LPM Routes (FIB) 12K
L3 IPv6 Host Entries (FIB) 4K
L3 IPv6 LPM Routes (FIB) 6K
Hardware Tunnels/Trunks 128
Flows/ACLs 2K
Meters 2K
Counters 2K
Packet Buffer Size per system 2MB
CPU Free-scale MPC8248 processor (400MHZ)
BUS Hi-Gig (Hi-Gig+ capable) & 32-bit 66MHZ PCI BUS & I2C BUS
Memory 256MB of SDRAM SO-DIMM is default (upgradeable to 512MB)
Flash Boot Flash: default 8MB upgradeable to 32MB
File System Flash: default 64MB of Compact FLASH for O/S storage
USB Port (Future Release) Philips ISP1761 USB2.0 port on the front panel
Main Switching Fabric ASIC OS6850-48 & P48: BCM56504 XGS Switch & BCM56502 XGS Switch
OS6850-48X & P48X: BCM56504 XGS Switch & BCM56504 XGS Switch
OS6850-24 & P24: BCM56502 XGS Switch
OS6850-24X & P24X: BCM56504 XGS Switch
10-Gigabit Ethernet Interface 10-Gigabit Ethernet XAUI interface
OS6850-48X & P48X: BCM8704
OS6850-24X & P24X: BCM8704
PHY OS6850-48 & P48: 5464SR & 5464R
OS6850-48X & P48X: 5464R
OS6850-24 & P24: 5464R & 5464SR
OS6850-24X & P24X: 5464R & 5464SR
Connectors XFP, SFP, and RJ45 connectors
Stacking 2 HI-Gig stacking ports supports up to 8 unit stacking topology
Console Port RS-232 Console Port (RJ-45 connector).
The console-protecting chip SEMTEC LCDA15C-6 is used along with the RJ45 connector.
POE /(Power over Ethernet) In-line Power Support POE with full compliance of IEEE 802.3af
EEPROM Board ID EEPROM Atmel 24C02 (on based-board)
Front Panel LED Front Panel 7-segment LED display for stack ID
Temperature Sensor Temperature Sensor National Semi-Conductor LM77 is supported
Thermal detection & Shutdown Thermal detection and shutdown is supported.
Clock Real Time Clock chip M41T11
Power Supply Pluggable main AC-to-DC and DC-to-DC Power Supply
Redundant Power Supply (RPS) AC-to-DC and DC-to-DC N+1 redundant Power Supplies are
supported.
Out of box SPS with selection for Mono 510W or dual 360W and RUP support
Fans 3 fans for the chassis with FAN failure detection. Additional fans built in the power supplies.
LEDS Per port Link/Activity/PoE monitoring LED support
System Power, BPS, and Diagnostic LED support
LEDS:
LED Status on Front Panel
o OK (Diag/OK/Fan fail/Temp fail)
o PRI (Primary/Secondary)
o PWR (Main Power Supply Status)
o RPS (Redundant Power Supply Status)
Single LED with dual color is used for each Gig Ethernet Port (link/activity/POE)
Single LED is used for each 10Gig Ethernet Port
Single LED is used for the fiber SFP ports.