Alcorn McBride Binloop User’s Manual Page 26
Enable SMPTE
Description: This command will Enable the SMPTE interface.
Comments: If the SMPTE module is configured to Generate, this command will cause the
clock to start generating at the configured Preroll time. If the SMPTE module is
configured to Read, it will start listening for SMPTE time code on the SMPTE
Input. If the SMPTE clock is in a paused state, this command will cause it to
resume from its current position.
Command: ES
Response: R
Disable SMPTE
Description: This command will disable the SMPTE interface.
Comments: If the SMPTE module is configured to Generate, this command will cause the
SMPTE clock to stop at its current time. If the SMPTE module is configured to
Read, this command will cause the SMPTE clock to stop running and ignore any
incoming time code.
Command: DS
Response: R
Pause SMPTE
Description: This command will pause the SMPTE clock at the next loop point.
Comments: This command only applies when the SMPTE module is in Generate mode and is
also configured to loop. When paused, the SMPTE clock can be resumed by
sending an Enable SMPTE command.
Command: PS
Response: R
Idle SMPTE
Description: This command will pause the SMPTE clock immediately.
Comments: When paused, the SMPTE clock can be resumed by sending an Enable SMPTE
command.
Command: IS
Response: R