User`s manual

Alcorn McBride Binloop User’s Manual Page 32
Get/Set Video Format
Description: This command will get or set the current video mode. This command sets the
A/V system to the appropriate frequency of 29.97 or 25 Hz. The reproducers will
also receive the command to change the frequency as well.
Parameters: x = mode number:
0 = NTSC
1 = PAL
Get Command: VF
Response: x
Example: Command: VF
Response: 0
Set Command: xVF
Response: R
Example: Command: 0VF
Response: R
Get/Set Synchronous Play Delay
Description: This command configures the synchronous play delay of the Binloop
reproducers. By default, this delay is 16 frames, but this setting allows you to
override that default if necessary. Be warned that decreasing this delay too
much will result in synchronization problems. The reproducers must have
adequate time to load the video or audio clip before it is capable of starting
playback.
Parameters: nnn is a number between 0-127 that represents the S-Play delay setting
0 – Use Reproducer Default Delay (16 Frames)
1-127 – Delay (in frames)
Get Command: SD
Response: nnn
Set Command: nnnSD
Response: R
Example: Set S-Play Delay to 8 frames: 8SD
Set S-Play Delay to the Reproducer Default: 0SD