Instructions & Assembly

WARNING! SHUT POWER OFF AT FUSE OR CIRCUIT BREAKER .
ASSEMBLING
ASSEMBLING
ASSEMBLING
ASSEMBLING THE
THE
THE
THE FIXTURE
FIXTURE
FIXTURE
FIXTURE (
(
(
( Fig.
Fig.
Fig.
Fig. 1
1
1
1 )
)
)
)
1. Shut off the power at the circuit breaker box. Remove old fixture
and all hardware from Junction Box.
2. Carefully unpack your new fixture and lay out all the parts on a
clear area. Take care not to lose any small parts necessary for
installation.
3. Attach the tube (K) to the coupling of the fixture body(L) , attach
the tube (J) and (I) onto the pipe nipple of the tube (K), by turning
it clockwise until tight.
4. Attach the ring(Q),plate(P), canopy(G) onto the pipe nipple of the
tube (I) , and lock them securely with the washer and hex nuts(F).
5. End of pipe nipple screw into single bar (D), place lock washer (C)
over end of nipple protruding through single bar and lock it
securely with the hex nut (A). Take this single bar assembly to
junction box with junction box screws (E), tighten screws securely
with screwdriver . The side of the single bar marked "GND" must
face to out.
6. While holding the fixture lamp towards the ceiling , connect the
electrical wires as Shown in Fig.2, making sure that all wire nuts
are secured. You may have to wrap the connections with electrical
tape. If your outlet has a ground wire (green or bare copper),
connect the fixture ground wire to it. Otherwise connect fixture s
ground wire directly to the Single bar with the green screw
provided. After wires are connected, tuck them carefully inside the
Junction Box.
7. Raise the fixture body on to the Junction box, aligning screws on
single bar with mounting hole in canopy and lock it securely with
the finial (H) . Attach the glass(M) to the socket holder and lock it
securely with the check ring(N).
8 . Install the light bulbs in accordance with the fixture s specifications.
NOTE:
NOTE:
NOTE:
NOTE: DO
DO
DO
DO NOT
NOT
NOT
NOT EXCEED
EXCEED
EXCEED
EXCEED THE
THE
THE
THE SPECIFIED
SPECIFIED
SPECIFIED
SPECIFIED WATTAGE.
WATTAGE.
WATTAGE.
WATTAGE.
Your
Your
Your
Your installation
installation
installation
installation is
is
is
is now
now
now
now complete
complete
complete
complete Return
Return
Return
Return power
power
power
power to
to
to
to the
the
the
the
junction
junction
junction
junction box
box
box
box and
and
and
and test
test
test
test the
the
the
the fixture.
fixture.
fixture.
fixture.
Fig.1
Fig. 2
White or
HOUSE
Black
WIRES
(Hot)
Smooth
FIXTURE
WIRES
Black or
Ribbed
WIRES
FIXTURE
Bare Copper(Ground)
FIXTURE
WIRES
Copper
(Ground)
HOUSE
(Neutral)
WIRES
White
Bare
Green or
WIRES
HOUSE
Listed
U
L
R
ASSEMBLING&INSTALLATIONINSTRUCTIONS

Summary of content (1 pages)