Operating instructions

FITTED EQUIPMENT
123
FITTED EQUIPMENT
122
Gas operation
Fig. 10
3
Gas operation :
Press button (3) :
The ignition process is activated automatically
by means of an automatic igniter.
Note: The flame extinguishes after
reaching the preset cooling compartment
temperature and ignites again if the cooling
compartment temperature increases again.
If the flame is not lit after the first ignition
attempt, the automatic igniter repeats the
ignition twice (duration 30 s) at time intervals
of 2 minutes. If the flame is not lit afterwards,
a fault is indicated.
Setting of cooling compartment
temperature
Fig. 11
7
8
Select the desired cooling compartment
temperature by pressing button (7) .
The LED display (8) of the selected
temperaturesetting is illuminated.
The scale starts with MIN position at the left
LED position (small bar = highest temperature)
and climbs up to MAX position at the right LED
position (large bar = lowest temperature).
Note: The temperature levels do not relate
to absolute temperature values.
Additional features
The brightness of the display reduces after a
few seconds if no other buttons are pressed.
The indicator lights again if a button is
pressed. Press the button again to activate
the required function.
Failures are indicated by flashing of the failure
indicator LED.
Should the door be kept open for too long
(more than 2 minutes), an acoustic signal is
initiated (pulsing whistle tone).
Should the electronic control detect any
failure, an acoustic signal will sound (pulsing
whistle tone). At the same time the display
starts flashing (for trouble-shooting, please
refer to page 129).
Gas operation with internal batteries
(optional)
An optional battery compartment in the
electronics case for internal (self-contained)
power supply of the electronics is available for
the model variants RMd 85x1 and RMD 85x5
(appliances with electronics).
.
Fig. 14
Load the battery compartment with batteries
(8 x AA 1.5 V) before operating the refrigerator.
All operating modes can be selected while the
on-board 12 V DC power supply is active. The
internal voltage is disconnected.
If the on-board 12 V DC power supply is not
present or there is an interruption of the mains
power supply during operation, the electronics
automatically switch to the internal (battery)
power supply. The refrigerator can now only be
operated in the gas mode.
All LED indicators except the GAS LED are not
lit during operation with internal batteries. The
GAS LED flashes every 15 seconds.
If a button is pressed, the temperature level
LEDs (7) also light.
DOMETIC REFRIGERATOR
If the battery voltage is too low, an acoustic
signal (whistle tone) sounds every 15 seconds.
Then replace the batteries in the battery
compartment.
Inserting / changing the batteries
Switch off the refrigerator, as described in
section 4.14 Shutting of the refrigerator.
Fig. 16
Opening right battery compartment
Fig. 15
Opening left battery compartment
open
press
press
open
1
1
2
Note: Batteries (8 x AA 1.5V) are not
included!
! WARNING:
• Observe the correct polarity!
Do not connect non-rechargeable
batteries to a charger.
Remove rechargeable batteries from the
battery compartment before charging.
Avoid short circuits on the contacts in the
battery compartment!
• Remove discharged batteries.
Remove the batteries from the battery
compartment if the refrigerator will not be
used for a long time.
• Do not mix different types of batteries.
Frame heating (fridge freezer models only)
All fridge freezer models are equipped with
a frame heating (12VDC/3,5W) around the
freezer compartment. During summer months
with high temperatures and humidity the metal
frame may have water droplets forming. To
evaporate these droplets switch on the frame
heating with button (6).
Fig. 18
6
8
The operating time of the frame heater can
be set to 2 hours, 5 hours or continuous
operation. After selecting the operating time
using the button (6), the temperature level
indicator (8) is extinguished for a short time to
show the set operating time for a few seconds.
The display then returns to the temperature
level indicator.
Operating time: 2 hours
Press button (6) once Display
1x
Operating time: 5 hours
Press button (6) twice Display
2x
Permanent operation
Press button (6) three times Display
3x