Operating instructions
FITTED EQUIPMENT
131
FITTED EQUIPMENT
130
Operation with on-board
12 v power supply
Indicator Fault Remedy
(2) and (8)
flashing and
acoustic signal 20s
230 V mode:
"230V" not
available or voltage
too low
Check mains power connection, mains voltage,
fuse
(4) and (8)
flashing and
acoustic signal 20s
12 V mode:
"12V" not available
or voltage too low
Check 12V connection, on-board battery, fuse
(3) and (8)
flashing and
acoustic signal 20s
Gas mode:
Flame not ignited
Check gas supply (gas bottle, gas valve)
Press the (8) button after clearing the fault
Acoustic signal,
15s at two minute
intervals
Interior lighting is
switched on
Close door, check door contact
(2) and (7)
flashing and
acoustic signal 20s
230 V mode:
230V heating
element defective
Arrange replacement of 230V heating element,
contact Customer Service
(4) and (7)
flashing and
acoustic signal 20s
12 V mode:
12V heating
element defective
Arrange replacement of 12V heating element,
contact Customer Service
(7)
flashing and
acoustic signal 20s
Temperature sensor
without contact or
defective
Contact Customer Service
(3) and (7)
flashing and
acoustic signal 20s
Burner defective
or cooling unit
defective
Check burner, burner nozzles, if
necessary contact Customer Service and
arrange replacement
Failure: The refrigerator does not cool in
230 V operation.
Possible cause Action you can take
On-board fuse defective Fit new fuse
Vehicle not connected to mains supply
voltage
Make a connection to a mains power supply
AES: Gas operation despite connection to the
mains supply voltage?
Appliance switches to gas operation due to
insufficient mains supply voltage (automatically
switches back to 230 V operation)
Heating element defective (please refer to
failure indication
Please inform Dometic Customer Services
Information on failure display and
trouble-shooting
• Refrigerators with an electronics system
(MES, AES) indicate the occurence of a
malfunction by the LED or display flashing.
• If a malfunction occurs, the indicator LED
“Failure” (8) flashes simultaneously. In the
case of AES models an acoustic alarm
sounds.
Before notifying the authorised Service Center,
please check whether:
• the instructions in section “Operating the
refrigerator” have been observed.
• the refrigerator stands level.
• it is possible to operate the refrigerator with
any available power source.
Status indicators
MES
Fig. 51
1 2 3 4 6 7 8
1 - Button ON / OFF
2 - Energy selector switch 230 V AC
3 - Energy selector switch GAS
4 - Energy selector switch 12V DC
6 - temperature level button
7 - temperature level display
8 - fault LED / GAS FAULT reset button
TROUBLESHOOTING