Operating instructions

FITTED EQUIPMENT
107
FITTED EQUIPMENT
106
and gas, electricity is given priority.
+22°C
ON
2 kW
OnOf
f
1. Start and step between the various power
steps (Off, 1kW, 2kW or 3kW) with the
+ button or – button. The set value is
displayed on the screen. When activated
the plus symbol changes colour to green.
(Certain boilers are equipped with max 2
kW, selecting 3kW is not possible in these
cases.)
2. The settings are ready and the boiler is
working at set temperature.
3. To switch off the electrical operation, step
with the – button to Off.
7. Heating with gas
Do as follows to activate heating with gas. If
both electricity and gas are selected, electricity
is given priority.
+22°C
ON
2 kW
OnOf
f
1. Start the gas operation by pressing On. The
On symbol is activated and changes colour
to green.
2. The settings are ready and the boiler is
working at set temperature.
3. In order to switch off gas operation,
press Off.
8. Unlocking the tool menu
It is possible to go from the setting menu to
the tool menu. Under the tool menu you can
access the other functions of the control panel,
described in section 9.
1. The control panel in setting menu.
Press the unlock symbol.
+22°C
ON
2 kW
OnOf
f
2. The control panel in unlocking menu. Press
on open padlock, then OK or MENU to
unlock the tools menu. When activated the
symbol changes colour to green.
OK
3. The control panel in setting menu with
unlocked tool menu. In order to get to the
tool menu, press the symbol.
+22°C
ON
2 kW
OnOf
f
9. The tool menu - functions
When you are in the tool menu (see section 8),
you can use the tools described below. Step
between the various tool fields by pressing the
up or down arrow symbols. You can always
leave the tool menu with the MENU button.
Note: Functions marked with * indicate
that the symbol for the function is displayed
on the control panel even if the accessory is
not installed!
5
A
7
4
5
2
8
1
9
36
10
Ext
Lan
Amp
11
14 16
15
13
12
1. Arrow symbols
Step between the various tool fields
by pressing the up or down arrow
symbols. You can always leave the tool
menu with the MENU button.
2. Clock
The clock must be set if automatic
nighttime mode or automatic start is to
be used. If 12V voltage is lost, the clock
will be reset and correct time will no
longer be displayed. This is prevented
with an optional AA battery backup.
3. Automatic night-time mode
This function is used when you want
to programme the central heating to
automatically lower the temperature
at night and raise the temperature in
the morning.
4. Starting the boiler automatically
This function is used to start the boiler
automatically at a later point of time.
With automatic start, the boiler works
for 24 hours and then stops. After that,
it repeats the automatic start once a
week; at the same day and time, as
long as the function is activated. For
automatic start to function, the On/Off
button must be set in the OFF position.
5. Constant pump operation
Cont.: With this function selected the
pump is permanently on. (NB., this
ALDE HEATING OPERATING INSTRUCTIONS