function limits the supply of hot water,
particularly when there is a low heating
requirement) Therm: With this function
selected the pump is controlled by the
panel/room sensor. This is the normal
operating mode for heating the vehicle
and obtaining a normal supply of hot
water. Factory setting is Therm.
A
6. *Pump Auto / 12V
In the Auto mode, the 230V pump
operates, and when 230V is
disconnected, the 12V pump starts. In
12V mode, the 12V pump is used even
if 230V is connected. The Auto function
is activated in the factory setting.
7. *Pump speed
The circulation pump’s capacity can be
remote controlled from the panel.
Note: A pump with remote control must be
installed in order that this function can be
used (see the manual for the vehicle, boat
or building).
8. *LPG bottle full/empty
This function is used in combination
with the cylinder changeover
(DuoComfort or DuoControl) and
indicates if the LPG bottle is full or
empty. This function can also be
used to control defroster heating of
the cylinder changeover using an
EisEx defroster.
Note: The cylinder changeover (DuoComfort
or DuoControl) must be installed in order for
this function to work (see the manual for the
vehicle, boat or building).
9. Automatic anti-bacterial mode
(legionella)
At 02.00 at night (if the clock is set)
the boiler starts and works according
to “Hot water boost” (see section 5).
This is in order to reduce the risk of
legionella. The function is deactivated in
the factory setting.
10. Offset (temperature adjustment)
Using this function, you can calibrate
the temperature on the panel if you
notice that the temperature (the
stabilised room temperature) is not the
same as the temperature shown on
the panel. This also applies to outdoor
temperature.
11. Button sound
With this function, you can activate
or deactivate the button sound. The
button sound is activated in the factory
setting.
12. Screen Brightness
Brightness: The brightness of the
display (working mode) can be adjusted
from 1 to 10. Factory setting is 5.
Standby brightness:
Off: Used to turn the display’s
backlighting off so that the display is
turned off (becomes dark) in standby
mode (the LED is still active).
On: Used to activate the backlighting
in the display (low lighting) in standby
mode (the LED is still active). Factory
setting is On.
Lan
13. Language
This function is used to reset the screen
between different languages. Available
languages are: English, French and
German. On the other hand, the service
menu is only in English (see section
10.1).
14. Tools / Key
Under Tools / Key you can lock or
unlock access to the tool menu.
Ext
15. *External start
This function is used when starting the
boiler from the outside, for example,
with GSM. When external start has
been activated, the control panel’s
On/Off button must be switched off
(see the assembly setting manual for
external start).
Note: To use this function, an external start
installation is required (see the manual for
the vehicle, boat or building).
*230 V
This function is used in connection with
starting the boiler when connection of 230
V to vehicle takes place from outside. When
the 230 V function has been activated the
control panel’s on/off button must be turned
off, but 12 V must be connected (the vehicle’s
main switch is on). Before turning off the
control panel with the on-/ off button set the
parameters/functions that you want the boiler
to have when it starts (230 V is connected).
Amp
16. *Load monitor
This function is used to prevent the
230V fuses being overloaded. If the
total power consumption of the vehicle,
boat or building exceeds the set value,
the boiler’s power will be automatically
reduced. On account of voltage
variations and tolerances, different
setting levels can be selected (for
example, for 6A fuse, one can choose
6 or 7 Amp setting). If the fuse does
not hold, choose a lower set value. The
function is deactivated in the factory
setting.
Note: The load monitor has to be installed
for the function to be used (see the manual
for the vehicle, boat or building).
10. Service and Resetting
the system
1
2
4
3
1. Service
With this function, you can see certain values
of the boiler on the screen. The values are
updated once a second
2. Resetting the system
With this function the panel can be reset to
factory setting. After resetting, the panel is set
as follows: the boiler in Off mode, electrical
operation 1kw, LPG heating in On mode and
indoor temperature 22°C.Other functions are
disconnected.
3. Translator
This function is used to enable an external
main panel to operate the boiler. If a main
panel is connected to the Alde panel, it is
activated with the On button, otherwise it must
always be set at Off. Factory setting is Off.
4. OK
To leave the tool menu, press OK or Menu.