Operating Instructions – Alde Compact 3020 HE
Operating instructions Checking the heating system before use The first time you start the heating system Starting the boiler Standby Settings menu Activated functions Tools menu Service menu Error messages Troubleshooting Resetting Activating installed functions Care and maintenance Important information Cable connection between boiler and control panel and assembly Install an Alde Compact 3020 High Efficiency together with a Truma Aventa Comfort AC and get a fully automatic climate system.
OPERATING INSTRUCTIONS ALDE COMPACT 3020 HIGH EFFICIENCY GB WARNING! Alde can accept no liability whatsoever for damage or injury resulting from failure to observe these instructions. Please read these instructions carefully before using the boiler for the first time. See separate directions for installation. SPECIFIED USE These instructions are approved for the Alde 3020 Compact HE fitted in caravans, motorhomes or buildings in accordance with CE 0402 no.
3. STARTING THE BOILER 1. The control panel and the boiler are switched off. 2. To start the boiler, press the On/Off button and the start-up display appears. The boiler starts with the last selected settings. 3020 High Efficiency 4. STANDBY NB! If “Standb. Screen” in the Backlight menu is set to Dark, the display goes out when it enters standby mode but lights up if you touch the screen. See settings under section 1, item 10. D E F G H I C 22°C B 6°C A Fri 18.30 J K A. Clock.
GB 5:1 SET THE DESIRED TEMPERATURE The temperature can be set between +5°C and +30°C in increments of 0.5°C. NB! If day or night auto is active, refer to section 7:1 items 4 and 5, temperature settings cannot be made. The plus and minus characters will then be grey. 1. The temperature displayed is the temperature which is currently set. +22°C 1 kW 2. Increase the temperature by pressing the + button. Reduce the temperature by pressing the – button. 3.
5:3 HEATING WITH ELECTRICITY Proceed as follows to activate heating with electricity. The more power (wattage) you select, the quicker heating will take. The priority of electricity or gas can be set if both are selected, see section 7:1 item 8. The boiler does not use a higher output than is required, even if 3kW has been selected. +22°C 1 kW 1. Use + or – to start and toggle between the various power modes (Off, 1 kW, 2 kW or 3 kW). The set value will be displayed on the screen.
ACTIVATED FUNCTIONS A GB 6. Pressing A (see figure 1) will enable continuing to activated functions (see figure 2). This screen shows the various functions that are activated. From here, you can go directly to each activated function and make new settings. NB! A symbol is only visible if any of the functions shown below are activated and/or installed.
7. TOOLS MENU The tools menu can be accessed from the settings menu. The other functions of the control panel can be changed from the tools menu. 1. Control panel showing the settings menu. Press the tool symbol to access the tools menu. +22°C 1 kW 7:1 TOOLS MENU – FUNCTIONS The following tools are available from the tools menu. A grey function button means the function has not been installed and/or activated. 3 17 4 11 Settings Settings Settings 2 5 10 12 16 1 6 9 13 15 18 19 7 8 1.
7. Return To return to the previous menu, press this symbol. 8. Prio setting With this function you can choose to prioritise (select) electricity or gas as the main alternative. 9. Button sound This function turns button sounds on and off. 10. Backlighting Standb. Screen can be set to three different modes, dark, bright and invert. Dark: Used to turn of screen backlight. The screen turns off (goes dark) in Standby.
15.*Booster This function enables setting two different speeds for one booster. Fan start and stop is controlled from the boiler. If the boiler’s circulation pump starts up, the fan on the booster will as well. When the circulation pump stops, the fan will continue to run for another six minutes and also stop unless the circulation pump has started again, i.e. giving automatic control of the booster fan. 16.*Setting room sensor With this function you can choose the temperature to be active.
GB 8. SERVICE MENU The Service menu is accessed by pressing Service (see figure 1). This function shows values from the boiler on the screen (figures 2 and 3). The values are updated every second. Figure 1 Figure 2 Figure 3 Service Settings Glycol Temp: 80° C Water Temp: Fan rotation: Current: 55° C 0RPM 0.0A Overheat: Deact Service PCB Temp: 20° C Ext Switch: deact Boiler: Panel: s737R300B 9.
9:1 TROUBLESHOOTING Always start by checking any error messages. The boiler will not start on gas • No LPG? • Is the main tap fully open? • Check that the type of LPG used is suitable for the prevailing outdoor temperature. Butane is unsuitable for use at temperatures lower than +10°C. Use propane instead. • If the boiler has not been operated for some time, or if the LPG cylinder is new, it may take longer than normal to light the boiler. • Check that power is being supplied to the boiler (> 11 V).
The first time you use the heating system, check that the correct accessories/functions are activated. This also applies when new accessories/functions have been added to the heating system. Activate accessories/functions by pressing Installed Accessories (see figure 1). This will take you to the activation menu for accessories/functions where a check in each function/accessory will activate it.
12. CARE AND MAINTENANCE • Checking and changing glycol mixture. Regularly check the heating system’s fluid level in the expansion tank. The level should be about 1 cm above the minimum mark, with the heating system cold. The heating system should be filled with a fluid mixture made up from water and ethylene glycol. For best results, use high-quality ready-mixed ethylene glycol (with inhibitors) intended for use in aluminium heating systems.
• • • • • • • • Always switch off the main isolating switch for the boiler when the vehicle is not in use. When washing the vehicle, do not spray water directly towards the flue. When camping in winter conditions, ensure the flue and exhaust air valves are kept clear of snow and ice. Ethylene glycol fluid may be heated even if the hot water heater is not filled with freshwater. The LPG boiler and electric element may be operated simultaneously.
CABLE CONNECTION COMPACT 3020 HIGH EFFICIENCY AND CONTROL PANEL 3020 113 Connect accessories to the boiler and control panel as shown in the diagram below. NB! Do not clamp 12 V cables or sensor cables together with 230 V cables. It is best not to position the cables close to one another. If the cables are bundled together, there is a greater risk of malfunction during operation.
GB 17
V-3020 05 Rev 1442, 2014-05-14 Alde International Systems AB Wrangels allé 90 • Box 11066 • S-291 11 Färlöv • Sweden Tel +46 (0)44 712 70 • Fax +46 (0)44 718 48 • www.alde.se • info@alde.