9:1 TROUBLESHOOTING
Always start by checking any error messages.
The boiler will not start on gas
• No LPG?
• Is the main tap fully open?
• Check that the type of LPG used is suitable for the prevailing outdoor temperature. Butane is unsuitable for use at
temperatures lower than +10°C. Use propane instead.
• If the boiler has not been operated for some time, or if the LPG cylinder is new, it may take longer than normal to
light the boiler.
• Check that power is being supplied to the boiler (> 11 V).
• Check that the fuse for the boiler has not blown.
• Check that the electrical connections on the boiler are secure and tight.
• If none of the above helps, contact a service workshop.
The electric element is not working
• Check that power (230 V) is being supplied to the electric element.
• Check that the relays tted to the boiler come on (a slight click can be heard from the relays when the electric ele-
ment is switched on at the control panel).
• If none of the above helps, contact a service workshop.
*ACC not working
• If the desired temperature cannot be reached with AC cooling, it may be because something has disturbed the AC
calibration. Turn off the AC with the AC button on the Alde panel and then on again. It may also be due to
insufcient cooling capacity.
10. RESETTING
The panel can be reset to its factory setting by pressing Reset. After resetting, the panel will be set as follows: Boiler –
Off mode; electrical operation – 1 kW; LPG heating – On mode; interior temperature – 22°C. Other functions are swit-
ched off. NB! The functions that are checked under Installed functions (see section 11) will not be affected by Reset.
Error messages in the error log are also affected by reset.
Functions marked with a (*) are accessories, which are not installed on all vehicles, refer to the vehicle
manufacturer's instructions.