Manual

Magna, Supra, & Ultra ImpacDor
®
Installation Instructions
TOOLS NEEDED
Pen or Pencil to Mark Holes
Drill
Crescent Wrench
Step Stool or Ladder
Retaining Tool
Receiving and Handling
Upon receipt of your traffic door, uncrate and check unit for shipping damage and/or missing parts. Any damage to
the crate or packaging material should be noted on the carrier bill of lading. Exterior damage may indicate concealed
damage.
Doorway Preparation
The key to proper operation of your traffic door is that the lintel is level and the jambs plumb and square with the
lintel. Building materials, which make up the lintel and jambs must be in good condition and solid to accommodate
the weight and action of your traffic door.
Traffic Door Preparation
Check the dimensions of your doorway with those of your traffic door. The overall height of the traffic door panels
(including hinge frame) should be ¾” less than the height of your doorway opening. Tighten the lower threaded
adjustor (A) aligning the lower pivot pin (B) with the bottom edge of your PVC door panel (C). Open the spring arms
(D) and slide down over the spacer plate (not shown in drawing).
Diagram 1
ImpacDor
®
1. Secure the upper mounting plate (F) centerline of
lintel. If necessary, use shims to insure it is level
and square with the doorjambs. Secure with
proper fasteners (not supplied) depending on
your lintel material or weld in place.
2. Position lower mounting plate (G) aligning the
lower pivot hole (H) with the pivot hole (I) in the
upper mounting plate (F). Secure with proper
fasteners (not supplied) or weld in place.
3. Raise traffic door panel to the vertical position
guiding lower pivot pin (B) into pivot hole (H) in
lower mounting plate (G). Be careful not to
release the bearing enclosed.
4. Align upper pivot pin (J) with pivot hole (I) in
upper mounting plate (F). Screw out lower
threaded adjustor (A), which will raise the door
panel into its proper position. Be sure spring
arms (D) slide over the upper adjustor (E) located
on the upper mounting plate (F). A space of 3/8”
should be left between the horizontal hinge arm
and the lintel of the opening.
5. Tighten locking nut (K) to secure door panel in
place.
FOR ANY QUESTIONS OR COMMENTS, PLEASE CONTACT AN ALECO REPRESENTATIVE
2720 E. Avalon Ave. Muscle Shoals, AL 35661 Phone (256) 248-2402 or toll free 1-800-633-3120
Fax: 1-800-750-9616 email: info@aleco.com
web: www.aleco.com
P/N 477133
(Rev 2/11/05)