Instructions / Assembly
14
7. Loop Detector
First insert the LOOP DETECTOR BOARD into the CONTROL BOARD, and then connect the twisted-pair
to the “17” and “18” terminals.
8. External Receiver
The BROWN wire of the external receiver should be connected into the “16” terminal.
The BLACK wire of the external receiver should be connected into the “13” terminal.
The RED wire of the external receiver should be connected into the “12” terminal.
9. Wired Keypad (12VDC)
The RED wire of the wired keypad should be connected into the “12” terminal.
The BLACK wire of the wired keypad should be connected into the “13” terminal.
The WHITE wire of the wired keypad should be connected into the “16” terminal.
The BLUE wire of the wired keypad should be connected into the “15” terminal.
Setting of the Control Board
1. DIP Switches
The DIP switches are used to set
the running time of the motor in
midway mode, auto close time of
the gate operator and fast change
the open/close direction which is
determined by the position of the
gate operator installed.
DIP Switch #1–#2: Running time
of the motor in Midway Mode
This mode enables user to drive the vehicle through the gate quickly when the gate opens to certain width.
DIP Switch #1: ON – 2 Seconds OFF – 0
DIP Switch #2: ON – 4 Seconds OFF – 0
NOTE: The midway function would be disabled if both DIP switches are turned off. Factory default
setting is disabled.
DIP Switch #3–#4: Auto close time of the gate operator
DIP Switch #3: ON – 30 Seconds OFF – 0
DIP Switch #4: ON – 60 Seconds OFF – 0
NOTE: The auto close function would be disabled if both dip switches are turned to off (factory
default setting).
DIP Switch #5: Left/Right open
ON – Right open (factory default setting).
OFF – Left open. Turn switch OFF to change the opening direction easy if necessary.
E.g. Running time of the operator in midway mode is 2+4=6 seconds.
E.g. Auto close time of the gate operator is 30+60=90 seconds.