MOBILE AIR CONDITIONER USER’S MANUAL Read Rules for Safe Operation and Instructions Carefully
CONTENTS 1. SAFETY RULES …………………………………………………………...2 2. NAME OF PARTS ………………………………………………………...3 3. ACCESSORIES …………………………………………………………….3 4. OPERATION PANEL OF THE AIR CONDITIONER ……………..…… 4-5 5. OPERATION AND INDICATION SECTIONS OF REMOTE CONTROLLER ……………………………………………….………..6-7 6. OPERATION METHOD………………………………………….…..… 8-10 7. KEY-OPERATING INSTRUCTION FOR THE AIR CONDITIONER..…………………………………………………..…. 11-13 8. INSTALLATION ..………………………………………………......… 13-15 9. MAINTENANCE …………………………………………………………15 10.
SAFETY RULES 1. Do not connect unit to any AC socket in disrepair. 2. Do not use in the following locations: A: Next to source of fire B: An area where oil is likely to splash. C: An area exposed to direct sunlight. D: An area where water is likely to splash. E: Near a bath, a shower or a swimming pool. 3. Never insert your fingers or any foreign objects into the air outlet. Take special care to warn children of these dangers. 4.
NAME OF PARTS REAR COVER FRONT COVER OPERATION PANEL AIR OUTLET AIR INLET AIR OUTLET WATER PUMP DRAIN HOSE REMOTE CONTROLLER AIR INLET AIR INLET POWER CORD CONTINUOUS DRAIN HOSE CASTER SIDE VIEW FRONT VIEW REAR VIEW Fig.1 ACCESSORIES PARTS PARTS NAME DUCT ASSEMBLY QUANTITY 1 INSTALLTION PLATE WATER PUMP DRAIN HOSE 1 Fig.2 Check all the accessories are included in the package and please refer to the installation instructions for their usage.
OPERATION PANEL OF THE AIR CONDITIONER i. A model display indicators (with electricity heating): ly light Set e e Fig.3 ii. A model display indicators (only cooling): light Set Fig.
● B model display indicators : F Receiver Fig.5 DISPLAY: Auto mode indicate Locked indicate Fan speed Heating mode indicate mode indicate F Swing indicate Cooling mode indicate Timer indicate Digital display Fig.6 Note: 1.The Auto Cooling Heating Dry mode indicators will not display in the Fan mode. 2.The relevant display light according the set content by remote controller. 3.
OPERATION OF THE REMOTE CONTROL Display Screen ON/OFF Button Press this button to start / stop air conditioner. For setting display Sleep Button For setting sleep function. AUTO SET TEMP PROGRAM Temp Adjustment Buttons Press “▼” to decrease temp. Press “▲” to increase temp.
Remote Controller Display Operating Mode Selection Display HEAT AUTO COOL DRY AUH Display It appears when pressing the AUH key is add in HEAT mode. Signal Emission Symbol It appears when control signal is emitted. Timer setting Display ON timer FAN OFF timer PROGRAM Wind Speed Selection Display Program AUT AUT SET TEMP PROGRAM Auto High speed Time Display Displays the time of clock or timing ON/OFF.
OPERATION METHOD AUTO, HEAT, COOL,FAN and DRY operation Auto Setting Operation Mode Heat Sweep Cool AUTO SET TEMP SLEEP ON/OFF TEMPERATURE MODE FAN SPEED AUH FAN SWEEP Dry 1 Temp Adjustment Buttons Press “ ▲ ” “ ▼ ” buttons to set temp as needed. 2 Switch On Press ON/OFF button to start air conditioner. 3 Airflow selection Press “FAN SWEEP” button to select airflow direction.
Clock Setting SET TEMP 1 2 Press “TIME” button to select , clock display will flash. Press “HOUR” button to change the hour display, each press of HOUR button will increase or decrease the time display by 1 hour; hour display will be changed continuously when pressing it continuously. SLEEP ON/OFF TEMPERATURE MODE FAN SPEED AUH FAN SWEEP TIME TIMER HOUR MINUTE RESET Press “MINUTE” button to change the minute display, (the method as step 2).
Off Timer SET TEMP Set the clock time as Clock Setting , 1 Press “TIME” button to select OFF, clock display will flash. SLEEP ON/OFF TEMPERATURE FAN SPEED MODE Press “HOUR” or “MINUTE” button; set the time to turn on the air conditioner on timer. At this time if user press “MINUTE” button, it will increase or decrease by 10 minutes. 2 AU FAN SWEEP H TIM TIMER E HOUR MINUT Press “TIMER” button to select E OFF RESET 3 . Note: 1.
Before Starting This Unit 1) Select a suitable location ,make sure you have easy access to an electrical outlet. 2) Install the Flexible Exhaust Hose and the Adjustable Window Slider Kit as depicted in Fig.7 Fig.7a NOTE: Step 2) is required only while using the cooling mode. Fig.7 Fig.7a 3) Plug the unit into the grounded electrical outlet. 4) Make sure the water pump drain hose is correctly installed, as Fig.8 . 5) Press the on/off button to turn on the unit. Fig.8 1.
Power supply: - Insert the plug of the air conditioner into a standard three prong outlet. 2. COOLING OPERATION - Connect the power and press the “ ON/OFF ” button. Press the “ MODE” button several times until the cooling indicator light comes on. - Press the “ TEMP SETTING” buttons▲or ▼ to select your desired room temperature. (60 -89 ) - Press the ″FAN SPEED″ button to choose the fan speed: Auto High Medium Low. 3. DEHUMIDIFYING OPERATION - Connect the power and press the “ ON/OFF ” button.
This is located on the back-side of the AC.) 8. - CONTINUOUS DRAINAGE When you plan to leave this unit unused for a long time or do not want to use the water pump, remove the rubber stopper from the continuous drainage plug and attach a tube or hose for continuous drainage. All the water in the water tank will drain once the continuous drainage plug is removed.(Under this condition, the water pump is not activated.) NOTE: 1. This type of air conditioner’ s waterproof level is IPX0.
Fig.10 A) TEMPORARY 1. 2. Attach one end of the duct to the exhaust air outlet of the mobile air conditioner, first fit the left side of the duct on the exhaust air panel, then the right side duct. Push it downwards, be sure to fix thoroughly.(See the fig.10 ) Put the end of duct to a nearby window.
MAINTENANCE IMPORTANT: 1) 2) 3) 4) BE SURE TO UNPLUG THE UNIT BEFORE CLEANING. DO NOT USE GASOLINE, THINNER OR OTHER CHEMICALS TO CLEAN THE UNIT. DO NOT WASH THE UNIT DIRECTLY UNDER A TAP OR USING A HOSE. IF THE POWER CORD IS DAMAGED, IT SHOULD BE REPAIRED BY MANUFACTURE OR ITS AGENCY. Fig.12 1. AIR FILTER - Clean the air filter at least once every two weeks to prevent inferior fan operation from dust build-up. Removal Pull out the filter cover and remove the air filter from the filter cover.
SUGGESTED PROBLEM POSSIBLE CAUSES REMEDIES 1. UNIT DOES NOT START - Water full indicator blinks, Dump the water in the water water tank is full. tank. WHEN PRESSING ON/OFF - Room temperature is higher Reset the temperature. BUTTON than the set temperature. (Heating mode) - Room temperature is lower Reset the temperature. than the set temperature. (Cooling mode). - LCDI plug was tripped. Press the reset button on the LCDI plug. Press On/Off button on the air conditioner. 2.