Page 4/4 Rev. 01/14/14 RECESSED / AL 1-LIGHT TID
AL 1-LIGHT
Technical Installation Data
HARD CEILING APPLICATIONS
The AL system is designed primarily for suspended acoustical ceilings. Fixture trim will not support drywall. Additional drywall support must be
provided adjacent to xture by ceiling installer.
The sketch to the right shows a method of installing the AL in a drywall ceiling. Note the ceiling must be installed after the AL housings. Also,
the access holes to the plenum through the xture must be cut by the contractor.
Reector
12"
"AL" Housing (Chassis)
Electrical Unit
Wall Rail
Wall Plate
10 ⅜"
Wall Line
8 ½"
9 15⁄32"
Parabolic Louver
Non-supporting
xture trim
Access to ceiling for
wiring and J-Box
inspection must be cut
in housing by installing
contractor
Install drywall into xture
trim and secure other end to
building structure
Ceiling Construction (by others)
10"