Instruction manual
A
lfaSpid Rotator  www.alfaspid.com  Page 12 
Page 12 of 23 
A
lfa Radio Ltd. 11211 - 154 St. Edmonton, Alberta, Canada T5M 1X8 780 466 5779 
 - Programmable Low Limit 
The Programmable Low Limit is a user adjustable counter-clockwise travel limit 
value. By increasing this value, the minimum counter-clockwise rotation travel 
can be restricted. Use the   and   buttons adjust the value. 
 - Programmable Reset Value 
The Programmable Reset Value can be set to either 0 degrees, or 180 degrees.  
This is the beam heading set when a power on reset event is triggered. If you 
wish to reset your rotator to south, set this value to 180. 
 - Preset 1 
P1 Thru P6 
 - Preset 6 
These 6 presets are user adjustable values that map to the 6 preset buttons on 
the optional mouse controller. You can set each preset to a commonly used 
beam heading, allowing rapid single button heading selections. 