- Auto ( CPU ) Mode 
In Auto Mode, the controller will respond to commands from control 
software running on an attached computer. The 
,  ,  ,   buttons 
can still be used, but pressing of any of them will cause cancelling the 
data from software. 
  Setup Mode 
The 
 button steps through the setup menu, for modes other than 
manual control operate as STOP. The display cycles through each of 
the setup menu items. 
 - Rotator Transmission 
 - Program Simulation 
 - Heading Adjust 
- Programmable High Limit  Default flashing “DOT” 180 
- Programmable Low Limit  Default not flashing “DOT” 180 
- Rotator Transmission 
This value defines the resolution of controller operation. 
1.0 means operating with 1 degree accuracy, 0.5 means 0.5 degree 
accuracy. On customized units this may be some other value. 
0.25, 0.5, 1.0 
- Program Simulation 
Program Simulation allows the user to set the serial communication 
protocol used by the rotator. When set to emulate another brand of 
rotator, the AlfaSpid will respond to commands. 
If your favourite software supports a rotator, chances are, the 
AlfaSpid will be able to interface to your software. There are 2 
modes available: 