BRIQUETTE TRAY INSTALLATION:
GAS CONNECTIONS:
NEVER CONNECT THE GRILL TO AN UNREGULATED GAS SUPPLY.
Total gas consumption (BTUH) with all
burners set on “HI” is a follows:
LIQUID PROPANE (LP):
Before proceeding, ensure the unit is fitted for LP gas. Connecting to an improper gas type will result in
poor performance and increased risk of damage or injury.
Installation of this cooking appliance must be made in accordace with local codes. In the absence of
local codes, this unit should be installed in accordance with the National Fuel Gas Code No. Z223.1/
NFPA 54, Natural Gas and Propane Installation code CSA B149-1 , or Propane Storage and Handling
Code B149.2.
Manifold pressure with LP Operating: 10.0” W.C. Non-operating: 11.2” W.C.
L.P. TANK REQUIREMENTS:
Use only a standard 20 Lb. (5 Gal.) propane gas cylinder (18-1/4” H x 12-1/4” Ø). The tank must be in-
stalled in the upright position. Do not use a dented or rusty LP tank as it may be hazardous and should
be checked by your LP supplier. Never use a cylinder with a damaged valve.
The LP gas cylinder must be constructed and marked in accordance with the specifications for LP gas
cylinders of the U.S. Department of Transportation (DOT). The cylinder must be provided with a shut off
valve terminating in an LP gas supply cylinder valve outlet specified, as applicable, for connection type
QCC1 in the standard for compressed gas cylinder valve outlet and inlet connections ANSI/CGA-V-I.
Remove top grills.
Briquette trays located over the
gas burners
MODEL: LP GAS NG GAS
ALXE-30SZ 63,100 64,200
ALXE-36SZ 82,000 85,800
ALXE-42SZ 84,200 88,200
ALXE-56SZ 122,000 124,000
ALXE-56BFG 116,900 122,900