Cutout Dimensions

Dimensions and specifications are subject to change without
notice. Please visit our website for the latest updates.
Grills & Insulated Jackets
Countertop Accessories
Note 1: All grills require a ½” NPT gas connection with 4” WC for natural gas and 10” Wc for liquid propane.
Note 2: All power supplies are 115 VAC-1ø-60 Hz. GFCI Receptacle recommended.
Note : Power requirement as stated on the corresponding grill (NOT DUE TO THE AIJ JACKET BY ITSELF).
3 5/8"
M
ODEL
CUTOUT DIMENSIONS NOTCH POWER
GAS
LINE
W
DHNYES NO AMPS
ALXE-30 28-1/2" 23" 10-1/4" 7/8" 1.44 / 0.91
ALXE-36 34-1/2" 23" 10-1/4 7/8" 1.44 / 0.91
ALXE-42 40-1/2" 23" 10-1/4" 7/8" 1.44 / 0.91
A
LXE-56 54-1/2" 23" 10-1/4" 7/8" 1.44 / 0.91
AIJ-30 33-1/4" 24-5/8" 11-1/4" 7/8"
AIJ-36 39-1/4" 24-5/8" 11-1/4" 7/8"
AIJ-42 45-1/4" 24-5/8" 11-1/4" 7/8"
AIJ-56 59-1/4" 24-5/8" 11-1/4" 7/8"
W
D
H
OVERHANG
BULLNOSE
SETBACK
N = NOTCH
MINIMUM
GRILLS
JACKETS
OUTLET FOR
ALXE UNITS
(REQUIRED)
OUTLET FOR
ALXE UNITS
(REQUIRED)
1
7/16" MAX.
1
" MIN.
C
OUNTER TOP FINISH
S
UBTOP
S
TRUCTURAL
S
UPPORT
ALXE GRILLS
BACK EDGE
DETAIL
MODEL
CUTOUT DIMENSIONS NOTCH SETBACK POWER
GAS
LINE
WATER
LINE
DRAIN
LINE
WDHN SYES NO AMPS
AXEVP 21-1/2" 22-1/2" 10-1/4" 1-3/8"
AXEVP-T10 4-1/2" 4-1/2"
1-5/8" 3/8"
AXESB2/AXESZ
13-1/4" 23" 10-1/4" 1/2"
AXEFW 13-1/4" 23" 10-1/4" 1/2"
ADT-14 13-1/4" 23" 9-1/4" 1/2" 1/2" 1"
ADT-24 23-1/4" 23" 10-1/4" 1/2" 1"
ADT-30 28-1/2" 23" 10-1/4" 3/4" 1/2" 1" + 2"
AGBC-14 13-1/4" 23" 9-1/4" 1/2" 1/2" 1"
AGBC-24 23-1/4" 23" 10-1/4" 1/2" 1"
AGBC-30 28-1/2" 23" 10-1/4" 7/8" 0.08 1-1/2"
ASK-T 13-1/4" 23" 10-1/4" 1/2" 1/2" 1"
APS-30 27-1/2" 8-3/4" 9-1/4" 1-3/8"
APS-30P 27-1/2" 15-1/4" 9-1/4" 1-3/8"
W
D
H
OVERHANG
BULLNOSE
SETBACK
N = NOTCH
MINIMUM
3 5/8"
W
D
S
OPTIONAL OUTLET FOR
COUNTER TOP APPLIANCES
(IE: BLENDER, ETC... )
OUTLET REQUIRED FOR
OPTIONAL LIGHT / SHELF
ASSEMBLY ON AGBC-30 UNIT
BARTENDERS
AND SINKS
BURNERS
PLATE
SHELVES
FILLER
TOWER
Note 1:
All burners require a ½” NPT gas connection with 4” WC for a natural gas and 10” Wc for liquid propane.
Note 2: All water lines are 1/8” compression or ½” NPSN unless otherwise shown.
Note 3: All drains sizes as shown are NPSM standard.
Note 4: All power supplies are 115 VAC-1ø-60 Hz. GFCI receptacle recommended.
Note: The AXEVP-T10 pot ller tower requires a minimum setback as shown
( OVER AND UNDER THE COUNTER) from the back wall for proper hardware installation.
Note: The AXEVP-T10 pot ller tower requires a 3/8” compression water line and comes with a 72” long copper line for eld connection.
An Insulated Jacket is required on all built-in grills
being set into combustable materials. Model: AIJ
26