Specifications
Document 90-00067 A  Algo Communication Products Ltd  (604) 454-3792 
2014-09-12  4500 Beedie St Burnaby BC Canada V5J 5L2  support@algosolutions.com 
Page 15    www.algosolutions.com    
Wiring Connections 
Network Connection 
The speaker provides a RJ45 jack for network connection. A cable run 
from the switch can be terminated to a modular jack with connection 
by patch cord, or terminated with a RJ45 plug. 
PoE (Power over Ethernet) must be 48V 350 mA IEEE 802.3af 
compliant whether provided by the network switch or injector. 
  Terminal Block Relay In 
 By default, these terminals are inactive. Connection options are a 
normally closed switch, normally open switch, Algo 1202 Call Button 
with large blue button, Algo 1203 single gang backlit wall switch, or 
EOL resistor termination. 
Terminal Block Relay Out 
 By default these terminals provide a contact closure when the 8188 
Ceiling Speaker is active. 
Blue LED Indicator 
The blue LED is visible through the speaker grill and by default will be 
on when the speaker is active. The blue LED will also be on during 
power up and boot process. 
The blue LED can also provide a heartbeat with a flash every 60 
seconds to indicate that the speaker is powered and connected to the 
network. 
If the 8188 Ceiling Speaker is in talkback mode the blue LED will be 
flashing. 
Reset Button 
  A recessed reset button (RST) next to the blue LED can only be 
used to reset the 8188 Ceiling Speaker at time of power up. To 
reset, reboot or power cycle the 8188 Ceiling Speaker. Wait until 
the blue LED flashes and then press and hold the reset button until 