User's Manual

READER HARDWARE INSTALLATION AND OPERATION CHAPTER 2
ALR-9890 – RR Hardware Setup Guide
DOC. CONTROL #8102XXX-000 REV A
18
Attach Circulator B to panel as shown in picture.
Figure 10- Circulator Assembly
Place a P-Clip around each hanging cable.
Measure down a little past the middle of each cable (approx. 7”-8”) and
attach the P-Clip to the panel.
Make sure the cable is not binding or strained at the circulator
connection.
Tighten the screws so that the cable inside the P-Clip cannot slide
through.
Check to make sure all of the connectors are at least hand tight.
If any of the connectors attached to the circulators have come loose
hand tighten, and then using the 5/16” open end wrench tighten a 1/8
turn only.
Caution: Do not over tighten connectors!
Route coax cables from the antennas to the reader according to your
system design specifications and secure them properly.
Attach the Type N-Female Antenna Lines A and B to the correct antenna
lines.
Align the connector for each cable with the reader antenna port, push
into the port, and finger-tighten the screw fitting.
5. Connect reader power.
Install the reader power supply. Be sure it is securely mounted.