User's Manual
READER HARDWARE INSTALLATION AND OPERATION CHAPTER 2
ALR-9890 – RR Hardware Setup Guide
DOC. CONTROL #8102XXX-000 REV A
18
• Attach Circulator B to panel as shown in picture.
Figure 10- Circulator Assembly
• Place a P-Clip around each hanging cable.
• Measure down a little past the middle of each cable (approx. 7”-8”) and
attach the P-Clip to the panel.
• Make sure the cable is not binding or strained at the circulator
connection.
• Tighten the screws so that the cable inside the P-Clip cannot slide
through.
• Check to make sure all of the connectors are at least hand tight.
• If any of the connectors attached to the circulators have come loose
hand tighten, and then using the 5/16” open end wrench tighten a 1/8
turn only.
• Caution: Do not over tighten connectors!
Route coax cables from the antennas to the reader according to your
system design specifications and secure them properly.
Attach the Type N-Female Antenna Lines A and B to the correct antenna
lines.
Align the connector for each cable with the reader antenna port, push
into the port, and finger-tighten the screw fitting.
5. Connect reader power.
Install the reader power supply. Be sure it is securely mounted.