User's Manual

CHAPTER 2 INSTALLATION AND OPERATION
NANOSCANNER READER USER GUIDE DOC # 8101029-000 REV A 10
© 2003 Alien Technology™
System Assembly and Bench Test
Assembling the Nanoscanner reader system is very easy.
We recommend you set up the system and verify its operation in a bench test
configuration before installing it in a live application.
You will need two available 120 VAC wall outlets.
Bench Test or Demo Connections
1. Situate the PC on a tabletop. Ensure the following conditions:
Two standard 120 VAC outlets are available nearby (one for reader, one
for PC if needed).
Sufficient space is available on the tabletop for the PC, reader and
antenna.
2. Connect the RS-232 cable to the reader.
Align the cable connector so that its shape and pins match the shape
and holes of the DB-9 serial port.
Push the aligned connector into the port.
Finger-tighten the screws to secure the cable/connector to the reader.
Antennas
Ports
To power supply &
120 VAC wall outlet
RS-232 to PC
Reader I/O panel
Power connect
I/O
(male)
A
nntena
Ports
RS-232
(female)
Tx
Rx