User's Guide Part 1

CHAPTER 7 WEB BASED APPLICATION EXAMPLES
NANOSCANNER READER USERGUIDE DOC ??? 54
© 2003 Alien Technology™
Example
Command
Response
>Get HeartbeatTime
>HeartbeatTime=30
Command
Response
>Set HeartbeatTime=60
>HeartbeatTime=60
G
ET COMMANDPORT
S
ET COMMANDPORT
The reader can be configured and operated over the network using standard
network sockets. The CommandPort settings are used to assign and retrieve the
exact port number used by the reader for this network connectivity.
The default setting for this command is 23 (the standard Telnet port)
Changes to this setting do not affect serial communication and/or Web
communication with the reader.
NOTE: Changes made with this command will take effect immediately.
Example
Command
Response
>Get CommandPort
>CommandPort=23
Command
Response
>Set CommandPort=10004
>CommandPort=10004
Network Commands – Web Based
Network commands are issued via the Web page to set up and access reader
networking parameters.
C
OMMANDS/OPERATIONS VIA WEB NETWORK TAB
Command equivalents found on the Web-based “Network” tab are:
Get DHCP
Toggles DHCP
On and Off
Web view
Network tab
covers all Get
and Set
network
commands.