System Design
The following Installation section provides basic guidance for configuring
components in your RFID system. We recommend you refer to the
Nanoscanner Reader Developer’s Guide for detailed system design
information before permanently mounting your equipment.
Installation
Installation involves all the same connection steps required for bench test.
However, instead of situating equipment on a tabletop, the reader and
antenna and their accessories will mounted in your application environment.
The photo below shows a reader with single antenna side-mounted at a
loading dock door for a portal application. This configuration may be used to
automatically identify tagged objects moving in and out of this door. Those
tagged objects may be pallets and cases on pallets, crates, equipment and
vehicles, or personnel.
Nanoscanner system configured for a single-antenna portal application. Shown
here at a loading dock.
A second (optional) antenna may be mounted on the opposite side of the
portal to better capture tags in a less than optimal position relative to the first
antenna (for example, tagged cases on the opposite side of a pallet).