User's Manual

ALXC2X USER MANUAL
Alinket Proprietary & Confidential Information
E-mail: sales@alinket.com Website: http://www.alinket.com
11
1.2 Range of operation
Table 3 Range of Operation-General Specification
Symbol
Description
Min
Max
Unit
Tg
General Operating temperature
-30
85
°C
To
Operating temperature
-40
85
°C
Ts
Storage temperature
-40
85
°C
VDDIO
IO Power supply
1.7
3.6
V
VDDBAT
Power supply
1.65
3.6
V
RFi
RF input power
0
dBm
MSL
Moisture Sensitivity Level
3
RoHS
Restriction of Hazardous Substances
Compliant
Table 4 Range of Operation-Voltages
Supply Power
Max +3.6 Volt
Non-Operating Temperature
- 30° to 85° Celsius
Voltage ripple
+/- 2%
Max. Values not exceeding operating
voltage
Power supply for the ALXC2X Controller will be provided by the host via the power pins.