Use and Care Manual
6000W Generator
26
Maintenance Schedule
Transporting / Storage
When transporting the generator, turn the engine switch and the fuel valve OFF. Keep the generator level to
prevent fuel spillage. Fuel vapor or spilled fuel may ignite.
First
5 Hours
REGULAR SERVICE
PER IOD
ITEM
Engine Oil
Check Level
Change Oil
Clean
Replace
Check
Check-adjust
Check-adjust
Check-adjust
Replace After every 300 Hrs.
Clean
Clean
Clean
Clean
Change
Spark Arrester
Spark Plug
Finger Guard
Sediment Cup
Area Around Muffler
And Controls
Change Gear Reduction
Oil (If Equipped)
Valve Clearqance
Idle Speed
Fuel Tank & Filter
• Fuel tube should be check or replace every 2 years.
• Combustion chamber should be cleaned by your servicing dealer every 500Hrs.
Air Filter
Pre-cleaner
Every
8 Hours
or Each use
Every
25 Hours
or Annually
Every
50 Hours
or Annually
Every
100 Hours
Annually
Air Cleaner Service (cont’d)
WARING
Contact with a hot engine or exhaust system can cause serious burns or fires. Let
the engine cool before transporting or storing the generator.
Take care not to drop or strike the generator when transporting. Do not place heavy objects on the generator.
Before storing the unit for an extended period:
1. Be sure the storage area is free of excessive humidity and dust.
2. Service according to the table below: