000W Generator Topic Page Limited Warranty 3 Safety Guidelines 5 General Precautions 6 Battery 15 Assembly 16 Operation 17 Inspection, Cleaning and Maintenance 21 Installation Specifications General Parts Listings 22 24 25 WARNING! READ AND UNDERSTAND ALL SAFETY PRECAUTIONS IN THIS MANUAL BEFORE OPERATING.
Owner’s Manual Limited Warranty All-Power America warrants to the original purchaser who uses the product in a consumer application (personal, residential or household usage) that all products covered under this warranty are free from defects in material and workmanship for one year from the date of purchase. All products covered by this limited warranty which are used in commercial applications (i.e.
2000W Generator Limited Warranty (cont’d) THIS WARRANTY DOES NOT COVER: • Merchandise sold as reconditioned, used as rental equipment, or floor or display models.
Safety Guidelines - Definitions Owner’s Manual This manual contains important information that you need to know and understand in order to protect YOUR SAFETY and to PREVENT EQUIPMENT PROBLEMS. The following symbols help you recognize this information. Please read the manual and pay attention to these sections. Save These Important Safety Instructions! Read and understand all of these safety instructions. Be sure to retain them for future use.
2000W Generator General Precautions WARNING! FAILURE TO FOLLOW THESE INSTRUCTIONS CAN RESULT IN SEVERE INJURY OR DEATH. CAUTION: FAILURE TO FOLLOW THESE INSTRUCTIONS CAN ALSO RESULT IN DAMAGE TO THE TOOL AND/OR THE ITEM YOU ARE WORKING ON. Carbon Monoxide When this tool is running, ensure that the area is well ventilated. Never run the engine in an enclosed area. Run the engine in an open area or with an exhaust evacuation system in an enclosed area.
General Precautions (cont’d) Owner’s Manual Gasoline and Oil (cont’d) • Do not smoke, or allow sparks, flames or other sources of ignition around the engine and fuel tank. Fuel vapors are explosive. • Keep grounded conductive objects, such as tools, away from exposed, live electrical parts and connections to avoid sparking or arcing. These events could ignite fumes or vapors. • Do not refill the fuel tank while the engine is running or while the engine is still hot.
2000W Generator General Precautions (cont’d) Work Area • Keep your work area clean and well lit. Cluttered benches and dark areas invite accidents. • Do not operate power tools in explosive atmospheres, such as in the presence of flammable liquids, gases, or dust. Generators create sparks which may ignite the dust or fumes. • Keep bystanders, children, and visitors away while operating a generator. Provide barriers or shields as needed.
General Precautions (cont’d) Owner’s Manual Electrical Safety (cont’d) • All connections and conduits from the generator to the load must only be installed by trained and licensed electricians, and in compliance with all relevant local, state, and federal electrical codes and standards, and other regulations where applicable. • The generator must be earth-grounded for fixed installations in accordance with all relevant electrical codes and standards before operation.
2000W Generator General Precautions (cont’d) Personal Safety (cont’d) • Avoid accidental starting. Make sure the power switch is in its “OFF” position, and disconnect the spark plug wire when not in use. • Remove adjusting keys or wrenches before turning the generator on. A wrench or a key that is left attached to a rotating part of the generator may result in personal injury. • Do not overreach. Keep proper footing and balance at all times. • Use safety equipment. Always wear eye protection.
Owner’s Manual General Precautions (cont’d) Servicing Maintain labels and name plates on the generator and engine. These carry important information. If unreadable or missing, contact All Power America immediately for a replacement. Generator service must be performed only qualified repair personnel. Service or maintenance performed by unqualified personnel could result in a risk of injury. When servicing a generator, use only identical replacement parts. Follow all appropriate instructions in this manual.
2000W Generator General Precautions (cont’d) Installation (cont’d) • If the generator is installed outdoors, it must be weatherproofed and should be soundproofed. It should not be run outdoors without protection to the generator and wiring conduit. • The generator weighs 62lbs. Two or more people should assist when moving or lifting this product. Never lift the generator using the engine or alternator lifting lugs.
General Precautions (cont’d) Owner’s Manual Mechanical (cont’d) • Do not operate the generator with safety guards removed. While the generator is running, do not attempt to reach around the safety guard for maintenance or any other reason. • Keep hands, arms, long hair, loose clothing, and jewelry away from moving parts. Be aware that when engine parts are moving fast they cannot be seen clearly. • Keep access doors on enclosures closed and locked when access is not required.
2000W Generator General Precautions (cont’d) Extension Cord If an extension cord (not included) is used, make sure to use only UL approved cords having the correct gauge and length according to the following table: Nameplate Amps (@ full load) 0’-50’ 0 - 5 16 5.1 - 8 16 8.1 - 12 14 12.
Owner’s Manual Battery This product does not need a battery.
2000W Generator Assembly Lug nuts 1-Handle Handle 2-Lugs 1. Place handle in pre-installed bolts. 2. Screw in lug nuts & tighten till secured.
Owner’s Manual Operation (cont’d) Powering 120 Volt AC Tools And Equipment: 1. Prior to powering tools and equipment, make sure the generator’s rated voltage, and amperage capacity (120V/AC @ 13.75 AMPs) is adequate to supply all electrical loads that the unit will power. If powering exceeds the generator’s capacity, it may be necessary to group one or more of the tools and/or equipment for connection to a separate generator.
00W Generator Operation (cont’d) Powering 12 Volt DC tools and Equipment: 1. Prior to powering tools and equipment, make sure the generator’s rated voltage, and amperage capacity (12V/DC @ 8.3 AMPs) is adequate to supply all electrical loads that the unit will power. If powering exceeds the generator’s capacity, it may be necessary to group one or more of the tools and/or equipment for connection to a separate generator. 2.
Owner’s Manual Inspection, Cleaning, and Maintenance WARNING! ALWAYS MAKE SURE THE ENGINE POWER SWITCH IS IN ITS “OFF” POSITION. DISCONNECT THE SPARK PLUG WIRE FROM THE ENGINE. AND ALLOW SUFFICIENT TIME FOR THE ENGINE AND GENERATOR TO COMPLETELY COOL BEFORE PERFORMING ANY INSPECTIONS, MAINTENANCE, OR CLEANING. • Before each use, inspect the generator.
2000W Generator Installation NOTE: PRIOR TO POWERING TOOLS AND EQUIPMENT MAKE SURE THE GENERATOR’S RATED VOLTAGE, WATTAGE AND AMPERAGE CAPACITY (120V@-13.75AMPs) IS ADEQUATE TO SUPPLY ALL ELECTRICAL LOADS THAT THE UNIT WILL POWER. IF POWERING EXCEEDS THE GENERATOR’S CAPACITY, IT MAY BE NECCESSARY TO GROUP ONE OR MORE OF THE TOOLS AND/OR EQUIPMENT FOR CONNECTION TO A SEPERATE GENERATOR. Electrical and other permits may be required for the installation of emergency power systems.
Owner’s Manual Installation (cont’d) Supporting and Mounting Mount the generator on a concrete slab capable of supporting the weight of the generator. The slab must extend on all sides beyond the frame by at least one foot. Contact a cement contractor for slab specifications if necessary. Attach the frame to the concrete slab using 3/8” diameter expansion anchor bolts (not supplied).
2000W Generator Specifications AC electrical Current Output 120V @ 13.75Amps, 60Hz Continous/rated Wattage 1,650 Peak Wattage 2,000 Outlet two 120V AC, 3-prong grounded DC electrical Current Output 12V/DC @ 8.3A Gasoline engine Horsepower Type 4 Displacement 119cc Oil capacity 0.6 liters EPA approved yes Type Unleaded gasoline Capacity 2 gallons (7.5 liters) Running time 9.
2000W Generator General Parts Listing (cont’d) APA Part No. Part.
General Parts Listing (cont’d) Owner’s Manual APA Part No. Part.
2000W Generator General Parts Listing (cont’d) APA Part No. Part.
General Parts Listing (cont’d) Owner’s Manual APA Part No. Part.
2000W Generator General Parts Listing (cont’d) APA Part No. Part.
General Parts Listing (cont’d) Owner’s Manual APA Part No. Part.
2000W Generator General Parts Listing (cont’d) APA Part No. Part. No Description AAPG 3010-154-LF GB5787-86 Screw M6_25 APG 3010-155-LF 34410/168F Engine stop cable APG 3010-156-LF 34510/168F Ignition coil APG 3010-157-LF 34310/168F Spark plug cap APG 3010-158-LF 34500/168F Ignition coil assembly APG 3010-159-LF 27500 Flywheel APG 3010-160-LF 19722 Flywheel fan APG 3010-161-LF 27371/168F Starting flange APG 3010-162-LF 27515/168F Nut M14-1.
General Parts Listing (cont’d) Owner’s Manual APA Part No. Part.