7. Stopping Your Generator
Step I: Disconnect all electrical plugs from the generator outlets before turning
off the generator7
Step I1: Turn off the "AIR" switch on the generator.
Step II1: Set the speed level in the "run" position, operating the generator for
about three minutes with nothing plugged in. Note: Do Not stop the generator
without this step, as the operating temperature of the engine will increase thereby
damaging the unit.
Step IV: Depress the "stop" lever
Step V: If the unit has an electric starter, turn the key to the "off" position.
1. Move the fuel lever to the "S" position.
Step VI: Retract the recoil starter handle until you feel resistance. (At this point
both the intake and exhaust valves are closed). Leave the handle in the position
as it prevents damp air from entering the engine and thereby prevents rust from
forming.
Warning:
Should the engine continue to operate when the speed lever is placed in
the "Stop" position, either turn the fuel valve to the "Close" position or
loosen the nut of the high pressure fuel pipe on the pump side of the
engine. If you do this, remember to tighten it again before attempting to
start the engine.
Do not attempt to stop the engine with the decompression lever.
Always make certain that all electrical plugs are removed from the
generator outlets before turning off your generator.