Manual

Owner's Manual
Operation .........
/
_ OTE: THE PARTS LISTED ABOVE ARE HELPFUL FOR LOCATING THE
CONTROLS MENTIONED BELOW,
7500W Generator
Operation (cont'd)
Starting
1, Put the engine switch on the "RUN" position.
The engine switch enables and disables the ignition
system.
STOP: To stop the engine
RUN: To run the engine
START: To Start the engine
2. The fuel valve is located under the fuel tank . When
CAUTION: PRIOR TO FIRST USING THE GENERATOR, THE ENGINE MUST BE
FILLED WiTH OiL OF A HiGH QUALITY SAE 10W-30 GRADE ENGINE OIL,
TO DO SO, UNSCREW AND REMOVE THE ENGINE'S OIL DiPSTiCK LOCATED
AT THE BOTTOM OF THE ENGINE CRANKCASE. FiLL THE ENGINE'S
CRANKCASE UNTIL THE OIL LEVEL IS LEVEL WiTH THE UPPER MARKED
LINE ON THE DIPSTICK, THEN SCREW THE DIPSTICK BACK INTO
THE OIL FILL HOLE.
Before Starting the Generator Fuel tank capacity:25L(6.6gallons)
1. Check that the engine power switch is in its
"OFF" position.
2. Before the first use, remove the fuel
tank cap and fill the fuel tank with unteaded
gasofine. When fuefing, be sure that the
fuel strainer is in place. Replace the fuel
tank cap. Thereafter, check the engine's
fuel gauge for the amount of unleaded
gasoline in the fuel tank. If necessary, FUEL TAf_K CAP
refil} the fuel tank with unleaded gasoline;
the generator must be turned off and
cooled down before refilling the fuel tank,
Use gasoline with a pump octane rating of 90 or higher.
We recommend unleaded gasoling because it produces
fewer engine and spark plug deposits and extends
exhaust system life.
Never use stale or contaminated gasoline or oil/gasoline .....
mixture. Avoid getting dirt or water in the fuel tank.
Owner's Manual
Operation (cont'd)
the valve lever is in the ON position, fuel is allowed
to flow from the fuel tank to the carburetor. Be sure
to return the fuel valve lever to the "OFF" position after
stopping the engine.
3. To start a cold engine, move the choke lever to the
"Start" position. To restart a warm engine, leave the
choke lever in the "RUN" position.
The choke lever opens and closes the choke valve in
the carburetor.
The "Start" position enriches the fuel mixture from
starting a cold engine.
The "RUN" position provides the correct fuel mixture
for operation after starting, and for restarting a warm
engine.
7500W Generator
Starting
4. Operate the Recoil Start:
Puff the starter grip lightly until you feel resistance,
then puff bdsMy. Return the starter grip gently.
Pulling the starter grip operates the recoil start to
crank the engine
Operate the Electric start:
Push and hold the engine switch on the "START"
position for 3-5s and crank the engine.
5. If the choke has been moved to the "Start" position
to start the engine, gradually move it to the "RUN"
position as the engine warms up.
Stopping Engine
1. Turn the engine switch to the "STOP" position.
2. Turn the fuel valve lever to the "OFF" position.
When the engine is not in use, leave the fuel valve in
the "OFF" position to prevent carburetor flooding
and to reduce the possibility of fuel leakage.
Operation (cont'd)
Powering 120 Volt AC Tools And Equipment:
1. Pdor to powering tools and equipment, make sure the generator's rated voltage, and amperage
capacity (120 V AC @ 50 AM Ps) is adequate to supply all electrical {cads that the unit will
power. If powering exceeds the generator's capacity, it may be necessary to group one or more
of the tools and/or equipment for connection to a separate generator.
CAUTION: ATTEMPTING TO POWER SENSITIVE ELECTRONIC EQUIPMENT
_ ITHOUT THE USE OF AN APPROVED LINE CONDITIONER MAY CAUSE
DAMAGE TO THE EQUIPMENT. ALL-POWER IS NOT RESPONSIBLE FOR
ANY DIRECT OR INDIRECT DAMAGE CAUSED BY FAILURE TO USE AN
APPROVED LINE CONDITIONER,
2. Once the generator is running, simply connect the power cords of 120 volt AC powered
tools and equipment into the 120 volt AC dual outlets.
L_ NOTE: THE GENERATOR FEATURES AN AC NON-FUSE THERMAL PROTECTOR
TO PROTECT THE AC CIRCUIT IN CASE OF AN OVERLOAD. SHOULD
AN OVERLOAD OCCUR, THE BREAKER WILL POP,
3. Disconnect all electrical powered tools and equipment from the generator's 120 volt AC
duel outlets.
4. After the engine and generator have completely cooled, store generator in a safe, clean, dry
location (if not already installed).