Operating Guide

24 | ALL POWER™ WP200 WATER PUMP www.allpoweramerica.com
24 TROUBLESHOOTING | OWNER’S MANUAL
TROUBLESHOOTING GUIDE
The following troubleshooting guide is recommended for basic or common problems;
if there’s an issue with the generator that is not listed, please call 1-888-896-6881.
Problem Probable Cause Solution
No Pump Output
1. Pump not primed. 1. Prime pump.
2. Hose collapsed, cut or punctured. 2. Replace suction hose.
3. Strainer not completely underwater.
3. Sink the strainer and the end of a suction hose completely
underwater.
4. Air leak at connector. 4. Refuel.
5. Strainer clogged. 5. Drain fuel tank and carburetor. Refuel with fresh gasoline.
6. Excessive head. 6. Remove and inspect spark plug. Clean, gap or replace spark plug.
Low Pump Output
1. Hose collapsed, damaged, too long or
diameter too small.
1. Replace suction hose.
2. Air leak at connector.
2. Replace sealing washer if missing or damaged. Tighten hose
connector and clamp.
3. Strainer clogged. 3. Clean debris from strainer.
4. Hose damaged, too long, or diameter too
small.
4. Replace discharge hose.
5. Marginal Head 5. Relocate pump and/or hoses to reduce head.