Installation Instructions

Instruction Manual/Instrucciones
Questions?/¿Preguntas? 1-800-334-6871 ConsumerProducts@cooperlighting.com
1
4. Remove access cover (D) from parts bag.
5. Install the first conduit connector and conduit
(sold separately) into the access cover (D).
6. Feed supply wires into conduit and make wiring
connections as described in “Wiring Your Fixture”.
7. Attach access cover (D) to the light fixture (A)
using the two access cover mounting screws (F)
provided (Fig. 1).
NOTE: Make sure all wiring is placed into the arm
prior to tightening the access cover screws (F).
8. Using the three mounting screws (E) provided, bolt
the housing (A) to the mounting surface.
9. Connect second conduit and conduit connector at
the junction box (Fig. 2).
10. Fasten lens assembly (B) to housing (A) using the
two lens assembly lock screws (G) and two washers
(I) provided (Fig. 3).
WIRING YOUR FIXTURE
1. Turn off the power at the main fuse/breaker box.
2. Attach ground wire that is attached to fixture
housing (A) to the junction box earth ground wire.
3. Connect the black fixture wire to the black supply
wire (hot). Attach UL approved wire connector
(sold separately).
4. Connect the white fixture wire to the white supply
wire (neutral). Attach UL approved wire connector
(sold separately).
NOTE: Be careful to connect the wires correctly. Make
sure no bare strands of wire extend from the wire nut or
other approved wire connectors (sold separately).
INSTALLING THE BULB
1. Screw the bulb (C) securely into socket.
2. Back the bulb (C) out one or two turns, then screw
bulb (C) back to insure proper position in socket.
3. Turn power back ON.
INSTALLING THE OPTIONAL LIGHT SHIELD/
REFLECTOR
NOTE: Sometimes fixtures are installed in locations
that receive too much reflected light. The photo sensor
may have trouble telling the difference between daylight
and light from the fixture. Also, if the fixture is in a
shadowy location, it may think it is always night time.
The light shield/reflector can be used to block or
channel light to the photo sensor.
PACKAGING CONTENTS/CONTENIDO DEL PAQUETE
ITEMS REQUIRED
(Purchase separately)
Phillips screwdriver
Adjustable wrench
Drill with 3/16 in. drill bit
1/2 in. diameter flexible conduit (if applicable, length depends on application)
1/2 in. watertight conduit connectors (if applicable)
Wire connectors
WARNINGS AND CAUTIONS
Read these instructions.
Keep these instructions.
Heed all warnings.
Follow all instructions.
For outdoor use only.
cULus LISTED for wet location use.
Connect fixture to a 120 volt, 60 Hz power source. Any other connection voids the warranty.
Fixture should be installed by persons with experience in household wiring or by a qualified
electrician. The electrical system, and the method of electrically connecting the fixture to it,
must be in accordance with the National Electrical Code and local building codes.
Always use same wattage and type of bulb that was included with the fixture. Failure to do
so will void the warranty. See fixture for wattage.
Disconnect at fuse or circuit breaker before installing or servicing.
Disconnect power and allow fixture to cool before changing bulb or handling fixture.
Edges may cut. Handle with care.
Upside down installation can result in overheating or accumulation of water in fixture.
Install right side up.
MINIMUM 90° C SUPPLY CONDUCTORS.
Notice: Lamps contain mercury, dispose according to local, state, or federal laws. For
more information, visit: www.lamprecycle.org.
MOUNTING YOUR FIXTURE
NOTE: This fixture is intended to be conduit connected to a properly installed and properly
grounded metal weatherproof junction box (not included). All conduit connectors, conduit, and
junction boxes (sold separately) should be UL Listed suitable for wet locations.
1. Using the pattern on the box, mark and drill holes for mounting.
NOTE: Mount this fixture in an upright position.
2. Install the two bottom mounting screws (E) first, leaving enough room between the
mounting screws and the mounting surface to accommodate mounting the fixture.
3. Screw the top mounting screw (E) into the predrilled hole and back the screw out. This
will leave the hole threaded and make installation of the fixture easier.
AL65FL
A. Fixture housing with
light sensor
Alojamiento del accesorio
con detector de luz
ENGLISH
E. (3) Mounting screws
(3) Tornillos de montaje
B. One-piece lens
assembly
Ensamblado del
lente de una
sola pieza
C. 65 watt fluorescent bulb
Bombilla fluorescente
de 65 vatios
D. Access cover
Cubierta de
acceso
G. (2) Lens assembly lock screws
(2) Tornillos de fijación del
ensamblado del lente
H. Green ground screw
(attached to fixture)
Tornillo de toma a
tierra verde
(conectado al accesorio)
F. (2) Access cover mounting screws (attached to fixture)
(2) Tornillos de la cubierta de acceso (conectado al accesorio)
I. (2) Washers
(2) Arandelas
J. Light shield/reflector (optional)
Escudo de luz/reflector (opcional)
Fig. 1
F
F
D
A
Fig. 2
Conduit
Junction
box
Conduit
connector
A
Fig. 3
A
B
G
I

Summary of content (4 pages)