Installation Guide
Installation Instructions 
Retro-Split Storm Collar Flashings 
2 of 2 
insert into the tab slots. Slide the plug and skirt assembly down the roof 
penetration to a height necessary to create a proper counter-flashing umbrella 
cover. 
Finally, fully open the stainless-steel hose clamp using a screw or nut driver. The 
Retro-Split Plug includes a pre-molded channel that will accept the width of the 
hose clamp. Position the clamp, and by using the worm drive action of the clamp, 
place it onto the now assembled Retro-Split Storm Collar skirt and plug 
assembly. Loosely tighten the clamp. 
Before fully finish tightening the clamp, position the assembled Retro-Split Collar 
downward and double check that the elevation is proper to cover the roof 
penetration flashing. The overlap provides a weatherproof counter-flashing 
umbrella. Do not force the Collar too tightly onto the flashing. This could cause 
the skirt to deform or open. 
After positioning the Collar, complete the tightening process of the stainless-steel 
clamp using a screw or nut driver. This compresses the tabs held within the plug 
slots by pressing the assembly onto the roof penetration. Be careful not to over 
tighten, as this can distort the new storm collar. 
Due to shrinkage of the EPDM rubber, and differences in temperature at 
each job site, the plug cut may not visually completely close, and a small 
gap observed. Use finger pressure to push the plug cut together while 
simultaneously tightening the clamp. 
.  