Owner`s manual
iNLEt PSi REqUiREmENtS
RESPIRATOR DESCRIPTION PSI RANGE 9990 PSI RANGE 9991 PSI RANGE 9992
9902 Series Full Face Mask 55-105 50-85 20-50
9903 Series Air Shield 90-120 72-98 25-46
9904 Series Deluxe Air Shield/Helmet 0-120 68-93 27-47
9909 Series Hardhat 80-120 65-115 23-47
9911 Series Saran Hood 85-110 55-85 30-48
AIR TEMPERATURE CONTROLLER
The Air Temperature Controller adjusts the amount
of air to the hood and adjusts air 25 degrees warmer
or cooler than the ambient air for use in cold or
hot environments. It includes a leather sheath to
protect the user from temperature extremes.
9990
PERSONAL AIR COOLER
The Personal Air Cooler is ideal in hot environments,
adjusting the air flow from high pressure air sources
as low as 25 degrees colder than ambient air for an
improved working environment.
9991
ADJUSTABLE FLOW CONTROL VALVE
The high pressure Adjustable Flow Control Valve
adjusts air flow from any high pressure air source for
greater comfort. It offers a large gripping handle that
makes it easy to use with a gloved hand. From the
lowest flow position, the control valve will deliver the
minimum flow required by NIOSH.
9992
HIGH PRESSURE SAR SYSTEMS
HIGH PRESSURE CONTROLLERS For use as a high pressure supplied air system, add one of the following flow control valves. All three offer a very
low profile design that won’t get in the way of work, meet NIOSH minimum flow requirements at their lowest setting and offer Hansen fittings with belt and clip assembly.
RESPIRATORS
13