Owner`s manual
1-WORKER 2-WORKER 5-WORKER 8+ -WORKER
Carry-Air w/CO Monitor 9873 9872 9875 9878
Carry-Air Inline w/CO Monitor 9878-100
Wall-Air w/CO Monitor 9873-40 9872-40 9875-40 9878-40
Carry-Air w/o CO Monitor 9872-W/O 9875-W/O 9878-W/O
Wall-Air w/o CO Monitor 9872-40W/O 9875-40W/O 9878-40W/O
Carry Panel (1-8 worker) 9878-100 9878-100 9878-100 9878-100
Wall Panel (1-12 worker) 9878-150 9878-150 9878-150 9878-150
HIGH PRESSURE FILTRATION PANELS AND ACCESSORIES
MULTI-REGULATOR AIR
FILTRATION PANEL
The unique design of this panel allows each regulator
to be individually adjusted at different pressure
settings, and also supplies separate outlets for air
tools. The viewing window on the case allows
monitoring of pressure gauges. A 16 gauge steel
stand for support is included as well as all brass
plumbing with quick-disconnect Hansen couplers.
9874MR 4-Worker
9876MR 6-Worker
INLINE FILTER PANELS
Our single outlet and single inlet inline filter panels
provide airline respirators a portable source of
breathable air while ideally designed for filtering air
anywhere within the airline system downstream from
outlets. We offer our inline filter panels in both
Carry-Air
™
and Wall-Air
™
configurations. All models
meet NIOSH requirements of point-of-attachment.
The Carry-Air
™
models provide up to 8 airline respirators
a portable source of up to 100 CFM of breathable air
from 5-125 psig. They’re house in a rugged Pelican
case for portability and protection. They also include
a support stand for stability and up-right operation.
Available with or without CO monitors. The AC/DC
powered Wall-Air
™
models provide up to 12 airline
respirators a portable source of up to 150 CFM of
breathable air from 5-125 psig. These units are easily
mounted on any wall to keep them out of the way
in your workshop area. Available with or without
CO monitors.
9878-100 Carry-Air
™
Inline Filter Panel
9878-150 Wall-Air
™
Inline Filter Panel
CARRY-AIR
™
AND WALL-AIR
™
FILTRATION PANELS
Allegro’s Air Filtration Panels convert shop air used for pneumatic tools and equip-
ment to clean breathable air. They provide from 1 to 8 airline respirators a portable
source of up to 15, 30, 60 or 100 CFM of breathable air from 5-125 psig. The
3-stage filtration system purifies compressed air removing water, oil and particulate
contaminants. An optional carbon monoxide monitor, which can be operated in AC
or DC mode, activates an audible alarm when the concentration of CO exceeds 10
ppm (set for 5 ppm in Canada).The pressure regulator includes a pressure gauge and
adjustment knob with locking ring. A pressure relief valve protects the CO monitor
and respirators in the event of regulator failure. The Carry-Air AC/DC-powered unit is
housed in a rugged Pelican case
for portability and protection.
It includes a support stand for
stability and up-right operation.
An AC/DC powered Wall-
Mount unit is also available.
Available with and without
CO monitors. All models
meet NIOSH requirements
for point-of-attachment.
9878-150
9878-100
9872-40
respirators
23
NOTE: All above air sources come standard with Foster/Hansen couplers. Other couplers are available on request.
ONLINE VIDEO
SUPPORT
www.allegrosafety.com
ALLEGRO AL
fiLtRAtiON PANEL SPECS
FILTRATION PANELS PART NO. MAX. FLOW MAX. INLET DIMENSIONS (W x H x D) WEIGHT (LBS.)
Carry-Air 1-worker 9873 15 CFM 150 psig 16"x 13"x 7" 11
2-worker 9872 Series 30 CFM 150 psig 18"x 12"x 6" 14
5-worker 9875 Series 60 CFM 150 psig 21"x 14½"x 6¾" 19
8-worker 9878 Series 100 CFM 150 psig 23"x 16½"x 7½" 25
Carry-Air Multi Regulator 4-worker* 9874 MR 60 CFM 125 psig 21"x 14½"x 6¾" 21
6-worker* 9876 MR 100 CFM 150 psig 23"x 16½"x 7½" 27
Carry-Air 100 CFM Panel 1-8 worker 9878-100 100 CFM 150 psig 23"x 16½"x 7½" 21
Wall-Air 1-worker 9873-40 15 CFM 150 psig 21¼"x 8¼"x 7¾" 11
2-worker 9872-40 Series 30 CFM 150 psig 21¼"x 8¼"x 7¾" 11
5-worker 9875-40 Series 60 CFM 150 psig 22"x 8½"x 7½" 15
8-worker 9878-40 Series 100 CFM 150 psig 25"x 14"x 7" 21
Wall-Air 150 CFM Panel 1-12 worker 9878-150 150 CFM 150 psig 22”x 19”x 10” 27