Datasheet
Linear Hall Effect Sensor ICs with Analog Output
A1324, A1325, 
and A1326
6
Allegro MicroSystems, Inc.
115 Northeast Cutoff
Worcester, Massachusetts 01615-0036 U.S.A.
1.508.853.5000; www.allegromicro.com
T
A
 = 25°C, and Sens
(25°C)1
 is the value of sensitivity at T
A
 = 25°C 
after temperature cycling T
A
 up to 150°C, down to –40°C, and 
back to up 25°C.
Linearity Sensitivity Error The 132x is designed to provide 
linear output in response to a ramping applied magnetic field. 
Consider two magnetic fields, B1 and B2. Ideally the sensitivity 
of a device is the same for both fields for a given supply voltage 
and temperature. Linearity sensitivity error is present when there 
is a difference between the sensitivities measured at B1 and B2. 
Linearity Sensitivity Error is calculated separately for the positive 
(LIN
ERR+
) and negative (LIN
ERR– 
) applied magnetic fields. Lin-
earity Sensitivity Error (%) is measured and defined as:
Sens
B(++)
Sens
B(+)
1–
Lin
ERR+
=
×
100%
Sens
B(– –)
Sens
B(–)
1–
Lin
ERR–
=
×
100%
(7)
and
 Lin
ERR
 = max(| Lin
ERR+
|
, |Lin
ERR–
| ) (8)
where:
|V
OUT(Bx) 
– V
OUT(Q)
|
B
X
Sens
Bx
=
(9)
and B(++), B(+), B(– –), and B(–) are positive and negative mag-
netic fields with respect to the quiescent voltage output such that 
|B(++)| > |B(+)| and |B(– –)| > |B(– )| .
Symmetry Sensitivity Error The magnetic sensitivity of a 
device is constant for any two applied magnetic fields of equal 
magnitude and opposite polarities. 
Symmetry Error (%), is measured and defined as:
Sens
B(+)
Sens
B(–)
1–
Sym
ERR
=
×
100%
(11)
where Sens
Bx
 is defined as in equation 9, and B(+), B(–) are posi-
tive and negative magnetic fields such that |B(+)| = |B(–)|.
Ratiometry Error The A132x features a ratiometric output. 
This means that the quiescent voltage output, V
OUT(Q) 
, magnetic 
sensitivity, Sens, and clamp voltages, V
CLPHIGH
 and V
CLPLOW 
, 
are proportional to the supply voltage, V
CC
. In other words, when 
the supply voltage increases or decreases by a certain percent-
age, each characteristic also increases or decreases by the same 
percentage. Error is the difference between the measured change 
in the supply voltage, relative to 5 V, and the measured change in 
each characteristic.
The ratiometric error in quiescent voltage output, Rat
VOUT(Q)
(%), for a given supply voltage, V
CC
, is defined as:
V
OUT(Q)VCC 
cV
OUT(Q)5V
V
CC 
c V
1–
Rat
VOUT(Q)
=
×
100%
(12)
The ratiometric error in magnetic sensitivity, Rat
SENS
 (%), for a 
given supply voltage, V
CC
, is defined as:
Sens
VCC 
cSens
5V
V
CC 
cV
1–
Rat
VOUT(Q)
=
×
100%
(13)