Installation manual

9-2 Frame 12 Installation
Figure 9.2 Enclosure Code B (NEMA/UL Type 1, IP21) and K (NEMA/UL Type 1, IP21
w/Conformal Coat)
Operating Temperatures
Frame 12 drives require a minimum of 5200 m
3
/h (3060 cfm) of cooling air.
200 mm
(8.0 in.) Min.
Powerful Performance, Flexible Control.
838 mm
(33.0 in.) Min.
Powerful Performance, Flexible Control.
PowerFlex
Drive Voltage Class Amp Rating
Surrounding Air Temperature
Normal Duty Heavy Duty
700H 400/480V AC
(540/650V DC)
820, 920 0 to 40° C (32 to 104°
F)
0 to 40° C (32 to 104° F)
400/480V AC
(540/650V DC)
1030 0 to 40° C (32 to 104°
F)
0 to 35° C (32 to 95° F)
600/690V AC
(810/932V DC)
820, 920 0 to 40° C (32 to 104°
F)
0 to 40° C (32 to 104° F)
600/690V AC
(810/932V DC)
1030 0 to 35° C (32 to 95° F) 0 to 40° C (32 to 104° F)
700S 400/480V AC
(540/650V DC)
820, 920 0 to 40° C (32 to 104°
F)
0 to 40° C (32 to 104° F)
400/480V AC
(540/650V DC)
1030 0 to 40° C (32 to 104°
F)
0 to 35° C (32 to 95° F)
600/690V AC
(810/932V DC)
820, 920 0 to 40° C (32 to 104°
F)
0 to 40° C (32 to 104° F)
600/690V AC
(810/932V DC)
1030 0 to 35° C (32 to 95° F) 0 to 35°
C (32 to 95° F)