Installation manual

3-18 Control Wiring for PowerFlex 700S Drives with Phase I Control
specifications. Open these switches for 12V dc operation, close them for 5V
dc operation.
Switches SW2-1, 3, and 5 are for the secondary encoder. Set these switches
to match the encoder output specifications. Open these switches for 12V dc
operation, close them for 5V dc operation.
Encoder Output Settings
Jumper J6 on the main control board configures the encoder power supply
for either 5V dc or 12V dc operation. Place the jumper on pins 1 and 2 for
12V operation. Place it on pins 2 and 3 for 5V dc operation.
Connecting SynchLink
SynchLink provides high-speed synchronization and communication
between multiple PowerFlex 700S drives (or other products with SynchLink
capability).
Class 1 LED Product
Refer to publication number 1756-TD008, SynchLink System Design Guide,
when planning and connecting the SynchLink network.
Connect cables to J9 (receive) and J8 (transmit) connectors on the bottom of
the Main Control Board. Push the plug into the socket until it produces an
audible click.
Important:Do not overtighten tie-wraps.
!
ATTENTION: Hazard of permanent eye damage exists when
using optical transmission equipment. This product emits intense
light and invisible radiation. Do not look into module ports or
fiber optic cable connectors.
J9 (Receive)