Installation manual

Installing Your Mass Storage System
Chapter 3
36
Figure 1.7 shows how to connect the Advisor2 Enclosure to a 1770-M10
system. Use the cable (P/N 966189-01) to connect each product and perform
these steps:
Figure 1.7
How
to Connect the 1770M10 System to the Advisor 2 Enclosure
Advisor2
Front View
Advisor2
Back View
1770M10
Mass Storage System
P/N 96618901
Connector Cable
13030
Advisor2
1. Match the power outlet voltage to the mass storage system’s voltage. for
example, if the power outlet is 220V ACF then change the electrical card
to 220V AC. (Refer to chapter 4.) We ship each mass storage system for
a 120V AC operation.
2. Connect one end of the connector cable to the disk drive port of the
Advisor 2 Enclosure.
3. Connect the other end to J21 of the 1770-M10 system.
4. Plug the power cable into the power outlet.
Important: If your system is equipped with a 1770-M10 system that is series
B or later, and your SFB2 is series A, revision D or later, set CPU dip switch 5
to the ON position. Series A 1770-M10 systems should have CPU dip switch 5
set to the OFF position. the series B 1770-M10 system will not operate with
SFB2 boards prior to series A, revision D.
Connecting to the Advisor 2
System