Specifications

Publication GMC-SG001E-EN-P June 2001
Motion Control Accessories 8-51
CE-Compliant In-Line Connection
This solution allows for a quick connect or disconnect at the cabinet wall while meeting CE requirements.
Link bulkhead and double-ended cables to create an interconnect in a single cable run.
Figure 8.59
Bulkhead and Double-Ended Connector Cables
Remote In-Line Connection
This solution provides a connection outside of a cabinet that uses flex and nonflex cables together for cost
reduction.
Figure 8.60
Remote Bulkhead Connection
IMPORTANT
To avoid control performance problems ensure the overall length of cable
combinations (system/axis module to motor) does not exceed 90 m (295.5 ft).
IMPORTANT
To avoid control performance problems ensure the overall length of cable
combinations (system/axis module to motor) does not exceed 90 m (295.5 ft).
1394
DANGER
RISK OF ELECTRICAL SHOCK. HIGH VOLTAGE MAY
EXIST UP TO FIVE MINUTES AFTER REMOVING POWER.
AB
ALLEN-BRADLEY
ALLEN-BRADLEY
AB
AB
ALLEN-BRADLEY
ALLEN-BRADLEY
AB
AB
AB
1326-CPB1-D /-CPC1-D
(power)
1326-CPB1-E /-CPC1-E
(power)
1326Ax Servo Motor (460V)
Maximum width
4.6 m (0.2 in.)
1326-CCUx -D (feedback)
1326-CCUx -E (feedback)
Optional mounting
through conductive
(metal) wall
1394
DANGER
RISK OF ELECTRICAL SHOCK. HIGH VOLTAGE MAY
EXIST UP TO FIVE MINUTES AFTER REMOVING POWER.
AB
ALLEN-BRADLEY
ALLEN-BRADLEY
AB
AB
ALLEN-BRADLEY
ALLEN-BRADLEY
AB
AB
AB
Maximum width
4.6 mm (0.2 in.)
1326Ax Servo Motors (460V)
Bracket mount
(not provided)
1326-CPB1-D /-CPC1-D
(power)
1326-CPB1-E /-CPC1-E
(power)
1326-CCUx -D (feedback)
1326-CCUx -E (feedback)