User manual

Chapter 1 Series 1700 Introduction
1-12 ADVANCED MICRO CONTROLS INC
Auxiliary Commands (continued)
Enter Read Status Mode -
This command puts the module in read status mode.
While in this mode, the module will transmit parameter values instead of position
and tachometer data. Four additional commands are enabled while in this mode that
allow you to specify which parameter values are to be read back.
Exit Read Status Mode -
This command places the module back into its normal
mode of operation. Position and tachometer data will be transmitted after this
command is accepted.
Read Status Mode
This special mode of operation allows you to read back the transducer setup
parameter values. Position and tachometer data is not transmitted while in this
mode.
Because the block transfer read length from a 1700 module is fixed, it is not to read back all
of the parameter values with a single block transfer. For this reason, four additional commands
are enabled while in this mode. These commands allow you to specify which parameters are to
be read back. Once specified, the parameter values will be transmitted with every block
transfer read until new parameters are specified or you exit read status mode.
For more information on read status mode, refer to Chapter 6, Backplane Programming.