114 POINT I/O Module and RSLogix 5000 Software Controller Tag Reference
1734-VHSC24
1 Channel 15…24V DC Very High-speed Counter
1734-VHSC5
1 Channel 5V DC Very High-speed Counter
Configuration Data Data Type Default
Value
Valid Data Values
Scalar SINT 0 Counter Config 5, 6, 8 only:
-128…+127 (0…255) Single Bit
only:
0, 1, 2, 4, 8, 16, 32, 64, -128
Output Ties 0
Out 0 Window 1
Out 0 Window 2
Out 0 Window 3
Out 0 Window 4
SINT
BIT 0
BIT 1
BIT 2
BIT 3
0
0=Output 0 Not Tied
1=Output 0 Tied to Window
Counter Config 3 (PWM):
Output 0 Window 1 PWM In
Output Ties 1
Out 1 Window 1
Out 1 Window 2
Out 1 Window 3
Out 1 Window 4
SINT
BIT 0
BIT 1
BIT 2
BIT 3
0
0=Output 1 Not Tied
1=Output 1 Tied to Window
Counter Config 3 (PWM):
Output 1 Window 1 PWM In
Rollover DINT 16,777,215 1…16,777,216
Preset (< Rollover) DINT 0 0…16,777,215
On Value 1
Off Value 1
On Value 2
Off Value 2
On Value 3
Off Value 3
On Value 4
Off Value 4
DINT
DINT
DINT
DINT
DINT
DINT
DINT
DINT
0
0
0
0
0
0
0
0
Counter Config 3, 5, 6, 7:
0…16,777,215
Counter Config 0, 1, 2, 4:
0 to Rollover Value
SS PWM Value
(<0 or >9500 =Hold Last State)
INT 0 0…9500
(0.00…95.00%)
SS Counter Control
SS Counter Reset
SS Counter Preset
SS Value Reset
(Stored / Accum. Count)
SINT
BIT 0
BIT 1
BIT 2
0
0=Count Unchanged
1=Count Cleared
0=Count Unchanged
1=Count Set to Preset
0=Count Unchanged
1=Count Cleared