AR2412 Panel Layout
Input sockets 24 balanced XLR inputs for
microphone and line level sources. The preamps
are built into the AR2412 rack and their Gain,
Pad and 48V phantom power is remote controlled
from the mixer via the dSNAKE link. The output
of the analogue preamps are converted to digital
format and transported via dSNAKE to be
processed and mixed at the GLD or Qu mixer.
The sockets are numbered 1-24. On GLD, any
input can be patched to any channel at the
console. On Qu, sockets are mapped one-to-one
to input channels.
Output sockets 12 balanced XLR outputs
operating at nominal +4dBu line level. Any signal
can be patched to any socket using the GLD I/O
screen or Qu Setup / Output Patch / dSNAKE
menu. The mixer defaults to a logical mapping of
these sockets to get you started.
EXPANDER port Cat5 cable link to
connect an AR84 or AB168 rack to add further
mic/line inputs and XLR line outputs. The GLD
system numbers these sockets as dSNAKE Exp
Inputs 1-16.
MONITOR port Cat5 cable link to connect
to Allen & Heath ME personal mixing system.
With a GLD system, the port is also compatible
with Aviom
TM
A-16 personal mixers.
dSNAKE port Cat5 cable link to connect
the AR2412 rack to the mixer. This carries the
inputs, outputs and the monitor port sends audio
to and from the rack as well as control for the
preamps and system status.
Maximum Cat5 cable length is 120m (396’)
depending on cable type.
Note that dSNAKE is not compatible with the
iLive ACE connection.
Fan A low noise fan ensures air movement
through the rack to keep the circuits within
operating temperature range.
Ensure good ventilation at the back of the
rack.
Mains power input IEC connector, fuse
and power ON/OFF push switch for the built-in
universal voltage power supply unit. This
accepts worldwide voltages from 100 to 240V AC
50/60Hz. Check that you have received the
correct mains lead for your territory.
Secure the cable in place using the plastic P-clip.
Use a T20 Torx screwdriver to refit the screw.
Read the Safety Instructions Sheet and information printed on the panel before operating.
By using this Allen & Heath product and the software within it you agree to be bound by the terms of
the relevant End User Licence Agreement (EULA), a copy of which can be found at: www.allen-
heath.com/legal.