Reference Guide User guide

GLD Touch Screen Reference V1.4 Issue 1 35 ALLEN&HEATH
7.4 Scene Recall Filter page
A Recall Filter can be set for each Scene to prevent certain
channels or parameters being overwritten by the Scene
when it is recalled. This lets you decide which parameters
to recall per Scene. A Recall Filter affects just the Scene it is
associated with.
Touch the Recall Filter button in the Scene Manager page
to open the filter window.
Use the tabs on the left to view the different parameter
groups. Swipe your finger up/down or left/right to navigate
through the list.
To set or clear filter items
1 - Single items - Touch to toggle a button:
Allow Parameter will be recalled
Block Parameter will not be recalled
2 - One parameter for all channels - Touch label at top.
3 - All parameters for one channel - Touch label on left.
4 - All items in the current tab - Touch Toggle All label.
5 - All items in all tabs - Touch Block All or Allow All button
at bottom left.
Touch Close to return to the main Scene Manager view.
5 4 3 2 1 Close
Scene Recall Filter parameters
For Inputs, FX Returns, FX mix, Grp, Aux, Main Mtx:
Preamp Gain, Pad, and 48V
Trim and Polarity
HPF
Insert In/Out and operating level
PEQ
GEQ
Dynamics Gate, Compressor and Limiter
Channel Fader
Channel Mute
Channel Pan
Routing assignments, Sends and Pan
Delay
Direct Out
DCA assignments
Name and Colour
Parameters that can be filtered for DCA Groups:
Channel assignments
Master Fader
Master Mute
Name and Colour
FX parameters:
Parameters for each of the 8FX units
SoftKeys:
Settings for each of the 10 SoftKeys
Other parameters that can be filtered:
Patchbay Input source, Inserts, Outputs
I/O Port Option card settings
Output Polarity
Talkback HPF
Ganging
dSNAKE Monitor Aviom/ME mode
Global Direct Out
Strip Assigns Left and/or Right banks
Note Blocking all items in the Recall Filter will prevent any
GLD parameters being overwritten when the Scene is
recalled.
A red dot lights in a screen tab when one or more items
have been blocked in that page.