Use and Care Guide

Cleaning your fire table top on a consistent and regular basis will help aid in a longer lasting top.
Cover your fire table with the included cover when not in use to protect it from the elements.
We recommend that your fire table be stored indoors during the winter months.
If it must be stored outside, it should ALWAYS be covered.
CARE AND MAINTENANCE
TROUBLESHOOTING
Troubleshooting
Problem Possible Cause Prevention/Cure
Burner will not light using igniter
LP gas tank valve is closed
Make sure regulator is securely attached to the LP gas tank per “Installing
LP
LP gas tank is low or empty Exchange, refill or replace LP gas tank
LP gas leak
1. Turn LP gas tank valve to “CLOSED”
2. Wait 5 minutes for gas to clear
3. Follow “Checking for Leaks” section
Battery needs to be changed
Electrode and burners are wet Wipe dry with cloth
Electrode cracked or broken - sparks at crack Replacement part(s) may be needed - contact Customer Care at 1-866-439-9800.
Wire loose or disconnected
Reconnect wire or replacement part(s) may be needed - contact Customer Care
a
Wire is shorting (sparking) between igniter and electrode Replacement part(s) may be needed - contact Customer Care at 1-866-439-9800
Bad igniter Replacement part(s) may be needed - contact Customer Care a
Burner will not light with match
No gas flow
Check if LP gas tank is empty
a. If empty, exchange, refill or replace LP gas tank
b. If LP gas tank is not empty, refer to “Sudden drop in gas flow or
reduced flame height (see below)
LP gas tank is low or empty Exchange, refill or replace LP gas tank
LP gas leak
1. Turn LP gas tank valve to “CLOSED”
2. Wait 5 minutes for gas to clear
3. Follow “Checking for Leaks” section
Coupling nut and regulator not fully connected
Turn the coupling nut about one-half to three-quarters additional turn until solid
stop. Tighten by hand only - do NOT use tools
Obstruction of gas flow
1. Clear burner/venturi tube
2. Check for bent or kinked hose
Disengagement of burner to valve Re-engage burner and valve
Spider webs or insect nest in burner/venturi tube Clean burner/venturi tube
Burner ports clogged or blocked Clean burner ports
Sudden drop in gas flow or
reduced flame height
Out of gas Exchange, refill or replace LP gas tank
Overfilling prevention device
may have been activated
1. Turn control knob to “
OFF”
2. Wait 30 seconds and light outdoor fireplace per “Lighting” section
3. If flames are still too low, reset the overfilling prevention device:
a. Turn control knob(s)
OFF”
b. Turn LP gas tank valve to “CLOSED”
c. Disconnect regulator
d. Turn control knobs to
(ON)
e. Wait one minute
f. Turn control knobs to
OFF”
g. Reconnect regulator and leak check connections, being careful not to
fully open valve
h. Light outdoor fireplace per “Lighting” section
Irregular flame pattern flame does
not run the full length of burner
Burner ports are clogged or blocked Clean burner ports
Flame is yellow or orange
New burner may have residual manufacturing oils Burn outdoor fireplace for 15 minutes and re-inspect
Spider webs or insect nest in burner/venturi tube Clean burner/venturi tube
Poor alignment of valve to burner/venturi tube Ensure burner/venturi tube is properly engaged with valve
Flame goes out
High or gusting winds Do not use outdoor fireplace in high winds
Low on LP gas Exchange, refill or replace LP gas tank
Excess flow valve tripped Refer to “Sudden drop in gas flow or reduced flame height”
Flashback (fire in venturi/burner tube(s)) Burner and/or burner/venturi tube is blocked Clean burner and/or burner/venturi tube
Flame seems to lose heat when burning
in cold
weather - temperature below 50ºF
Ice has built up on the outside of the LP gas
tank
because the vaporization process is
1. Turn off per “Turning Off” section
2. Replace with a spare LP gas tank
3. Reconnect LP gas tank per “Installing LP Gas Tank” section
4. Follow “Checking for Leaks” section
5. Light outdoor fireplace per “Lighting” section
too slow.
Gas Tank, then turn LP gas tank valve to “OPEN”
t 1-866-439-9800
t 1-866-439-9800.
If you have any questions or problems, please call our customer service department at 1-866-439-9800, 8 a.m. - 8 p.m.,
EST, Monday - Friday.
12
Replace the “AA A” battery (follow assembly step for inserting battery)