ALLEN + ROTH WATER-RESISTANT LAMINATE FLOORING INSTALLATION INSTRUCTIONS
Please read all the instructions before you begin the installation. Improper installation will void warranty.
CAUTION:
Use safety glasses and gloves when cutting laminate oors. Laminate oors will create wood dust; always use a protective
dust mask and cut the product in a well-ventilated area.
Never tap long edges; tap only as instructed in this guide.
Never use tools designed for other laminate ooring installation systems.
Never wax, polish, or use abrasive cleaners on laminate oors.
This laminate ooring product is not suitable for use in areas where the oor is prone to continuous moisture, such as but not
limited to, steam rooms and saunas. Do not install in rooms that have oor drains or sump pumps.
Do not install cabinets or a󰀩x any objects (eg. kitchen islands) to or through the laminate oor. Cabinets should be installed
before the laminate oor or a󰀩xed to the wall to prevent pinning the laminate oor.
Inspect every plank for defects or damage before installing it.
Do not tap laminate planks directly. Always tap against a scrap piece to protect the installed planks. Tap lightly and evenly as
tapping with excessive force can result in damage.
MANUFACTURER’S REQUIRED MINNESOTA DISCLOSURE – IMPORTANT HEALTH NOTICE: SOME OF THE BUILD-
ING MATERIALS USED IN THIS HOME (OR THESE BUILDING MATERIALS) EMIT FORMALDEHYDE. EYE, NOSE, AND
THROAT IRRITATION, HEADACHE, NAUSEA AND A VARIETY OF ASTHMA-LIKE SYMPTOMS, INCLUDING SHORTNESS
OF BREATH, HAVE BEEN REPORTED AS A RESULT OF FORMALDEHYDE EXPOSURE. ELDERLY PERSONS AND YOUNG
CHILDREN, AS WELL AS ANYONE WITH A HISTORY OF ASTHMA, ALLERGIES OR LUNG PROBLEMS, MAY BE AT GREAT-
ER RISK. RESEARCH IS CONTINUING ON THE POSSIBLE LONG-TERM EFFECTS OF EXPOSURE TO FORMALDEHYDE.
REDUCED VENTILATION MAY ALLOW FORMALDEHYDE AND OTHER CONTAMINANTS TO ACCUMULATE IN THE IN-
DOOR AIR. HIGH INDOOR TEMPERATURES AND HUMIDITY RAISE FORMALDEHYDE LEVELS. WHEN A HOME IS TO
BE LOCATED IN AREAS SUBJECT TO EXTREME SUMMER TEMPERATURES, AN AIR-CONDITIONING SYSTEM CAN BE
USED TO CONTROL INDOOR TEMPERATURE LEVELS. OTHER MEANS OF CONTROLLED MECHANICAL VENTILATION
CAN BE USED TO REDUCE LEVELS OF FORMALDEHYDE AND OTHER INDOOR CONTAMINANTS. IF YOU HAVE ANY
QUESTIONS REGARDING THE HEALTH EFFECTS OF FORMALDEHYDE, CONSULT YOUR DOCTOR OR LOCAL HEALTH
DEPARTMENT.
INTENDED USE
These laminate oors are designed to be used in interior, climate-controlled areas. Installation temperatures should
be at a minimum of 64°F (18°C) and relative humidity should be between 50% and 60%. These laminate oors can
be installed on grade, above grade or below grade. Laminate oors are designed as a oating oor system and are
not to be nailed, screwed, glued or attached in any way to the suboor.
TOOLS AND SUPPLIES
Saw (power saw, hand saw or guillotine-type cutter)
Measuring tape
Carpenter’s square
Utility knife
Pencil/marker
Pull bar
Tap block
Hammer/mallet
3/8” (10mm) spacers
Laminate oor underlayment max. 3mm (1/9 in.) thick
6 mil (0.15mm) thick vapor barrier (concrete installation
requirement)
2” (51mm) wide moisture-resistant adhesive tape
Flexible 100% silicone caulking (wet area installation
requirement)
1/2” (12mm) and 3/8” (10mm) compressible PE foam
backer rod (wet area installation requirement)
Safety glasses
Dust mask (NIOSH-designated)
Gloves