Specifications

800-TEC-ENGR
www.avg.net
A-32
Position Transducers/Sensors
DM960 SPECIFICATIONS
Input Power:
AC:
105-135 VAC or 210-270 VAC, 50/60 Hz, 5 W
DC: 8-30 VDC @ 0.25 A exclusive of load without optical
isolation, an external power supply is needed only for PNP
(sourcing) outputs
Operating Temperature:
-10 °F to 130 °F (-23 °C to 55 °C)
Position Transducer:
AVG Automation's RL210-G128 (128 Turns) or RL210-G064
(64 Turns)
Resolution: 10-bit-per-turn, 17-bits total over 128 turns
Output Format: BCD, Natural Binary, or Gray code
Maximum Cable Length between Resolver and DM960: 2500
ft (762 m) shielded
Resolver shaft speed: 3600 RPM (Max)
Resolver-to-digital decoder tracking speed: 1800 RPM
Display: 6-digit, 0.3" (7.62 mm) LEDS
Offset Capability: up to 128000 counts
PLC Synch Circuit (optional):
Input Logic:
0 to 24 VDC logic
Logic False: 0 to 0.8 V @ 3.2 mA
Logic True: 2.4 V @ 0.4 mA; Positive- and negative-edge
triggered.
PC Handshake strobe: 30-µs minimum width.
Data Latch Delay: Adjustable 200 µs to 30 ms. Factory set
at 3 ms ±20%
Optical Isolation (optional): 2500 Volts, on all I/Os except
resolver