User's Manual

www.biomark.com
2 Getting Started
2.1 Turning Reader On and Off
The reader can be powered on by any of the following methods:
Pressing and holding the OK button for 1 second.
Connecting the reader to the included AC power supply or USB port of a PC.
Upon powering up, the reader will display a splash screen and emit a short beep. This screen will display the
present firmware version in the bottom right corner. After approximately 1.5 seconds, the reader will display
the main screen.
NOTE: Operating ambient temperature of the HPR Lite reader must be between -20°C (-4°F) and +58°C
(+136.4°F) with relative humidity between 10% and 90%, non-condensing.
The reader can be powered off by any of the following methods:
Pressing and holding the OK button while in main screen. After approximately one second a
shutdown timer will appear. Continue holding the OK button until the reader sounds two beeps and
shuts down. The count down can be aborted by releasing the OK button.
The reader will automatically power off after certain period of inactivity. The inactivity time is user
adjustable and by default is set to 180 seconds (3 minutes). Pressing any button will reset the
timer.
V1.01.00V1.01.00
00000
7:13 PM
09/27/2017
MEMORY
Press and hold READ to
scan
READY
00000
7:13 PM
09/27/2017
MEMORY
Press and hold READ to
scan
READY
7:13 PM
09/27/2017
MEMORY
00000
Press and hold READ to
scan
READY
SHUTDOWN...
3
7:13 PM
09/27/2017
MEMORY
00000
Press and hold READ to
scan
READY
SHUTDOWN...
3
Screen during power up Main Screen